Sharp MX-M260 Service Manual page 74

Digital multifunctional system
Hide thumbs Also See for MX-M260:
Table of Contents

Advertisement

66-30
Purpose
Operation test/check
Function (Purpose)
Used to set the TEL/LIU.
Section
FAX
Item
Operation
Operation/procedure
When the relay state of the polarity reverse relay, the handset hook
switch, or the external telephone hook switch is changed, the content
of change is displayed regardless of the soft SW setup (real time). The
display of change is kept until an interruption command is supplied by
pressing the [SYSTEM SETTINGS] key.
Item
Signal low
HS2
HS1
RHS
EXHS
Note: Executable only when the FAX is installed.
66-31
Purpose
Setting
Function (Purpose)
Used to set the TEL/LIU.
Section
FAX
Item
Operation
Operation/Procedure
1. Enter the set value. (Valid only 1 to 5)
2. The entered bit is alternatively switched between "0" and "1" and
the target signal name is highlighted.
3. Press the [START] key to send the signal.
When the [CUSTUM SETTINGS] key is pressed, the output is terminated.
Note: Executable only when the FAX is installed.
66-32
Purpose
Operation test/check
Function (Purpose)
Receive data check
Section
FAX
Item
Operation
Operation/procedure
The fixed data received from the line are checked and the result is displayed.
When data are coincident, "OK" is displayed. When not, "NG" is displayed.
Note: Executable only when the FAX is installed.
66-33
Purpose
Operation test/check
Function (Purpose) Signal detection check
Section
FAX
Item
Operation
Operation/Procedure
Signal detection is checked and the result is displayed.
Note: Executable only when the FAX is installed.
66-34
Purpose
Operation test/check
Function (Purpose) Communication time measurement display
Section
FAX
Item
Operation
Notification contents
Signal high
ON
OFF
ON
OFF
ON
OFF
ON
OFF
MX-M260/M310/M260N/M310N SIMULATION 6 - 41
Operation/procedure
The send/receive test is performed, and the time required for send/
receive of the image data in the test is measured and displayed.
Communication
means
Setup on the user
Picture quality
side when executing
Density
communication
ECM
Sender information
From flag reception before sending of image
Send
Measuring
data until sending of RCP frame
range
From flag reception before reception of
Receive
image data until reception of RCP frame
Used to make communication not in a
Mode when measuring
simulation process but in the normal screen
and measure the time.
Enter the simulation for communication time
How to check the time
check and check the time.
Measuring unit
msec
When there are two or more send/receive operations of image data in
one communication, only the time of the last send/receive data near
the end is measured.
Note: Executable only when the FAX is installed.
66-37
Purpose
Adjustment/Setting/Check
Function (Purpose)
Speaker sound volume adjustment
Section
FAX
Operation/procedure
The following test sound is delivered to the line and the speaker to
adjust the sound kind and volume.
The send level to the line is the set value of soft SW.
The set values of the selected sound kind and volume are written to
each soft SW.
1. Sound kinds pattern
Sound kinds (Test sound)
RINGER
Call sound
Line monitor sound (Test
LINE MONITO
sound: communication
signal sound)
On-hook (Test sound,
ON HOOK
communication signal
sound)
SCAN FINISH
Scan finish sound
Communication finish
TX/RX FINISH
sound
DTMF
DTFM send sound
LAR: (MED. Value + 1)
MED: (SMA value +1) - (LAR value – 1)
SMA: 1 - (MED. Value + 1)
2. Sound volume pattern
Note: Executable only when the FAX is installed.
66-41
Purpose
Adjustment/Setting/Check
Function
CI signal check
(Purpose)
Operation/procedure
When the [START] key is pressed, the call signal from CI pin is
detected to deliver the call sound to the line and the speaker. The vol-
ume of call sound follows the soft SW.
Signal detection and delivery of pseudo-call sound at detection are
executed until the interruption command is provided by pressing the
[SYSTEM SETTINGS] key.
Note: Executable only when the FAX is installed.
: Memory send
: Normal Character
: Lighter
: ON
: OFF
Sound volume set value
DEF. LAR. MED. SMA.
DEF. LAR. MED. SMA.
DEF. LAR. MED. SMA.
DEF. LAR. MED. SMA.
DEF. LAR. MED. SMA.
DEF. LAR. MED. SMA.