Sharp MX-M260 Service Manual page 45

Digital multifunctional system
Hide thumbs Also See for MX-M260:
Table of Contents

Advertisement

9-4
Purpose
Operation test/check
Function (Purpose) Duplex motor RPM setting
Section
Duplex
Item
Operation
Operation/procedure
Enter the set value with the 10-key.
When the duplex motor setting is made, the duplex 2motor is also set
accordingly.
Setting range
1-13
Default
5
9-5
Purpose
Adjustment
Used to adjust the timing of switching from normal
Function
rotation to reverse rotation or from reverse rotation to
(Purpose)
normal rotation of the duplex motor.
Operation/procedure
1. Touch the item to set.
2. Enter the set value with the 10-key, and press the [START] key.
Item
Installation range
1
145mm/s
2
122mm/s
3
RIGHT 145mm/s
4
RIGHT 122mm/s
10
10-0
Purpose
Operation test/check
Function
Used to check the operation of the toner motor and its
(Purpose)
control circuit.
Image process
(Photoconductor/Developing/Transfer/Cleaning)
Section
Developer/Toner hopper
Item
Operation
Operation/procedure
Press the [START] key and operate the toner motor for 30 sec.
14
14-0
Purpose
Clear/Cancel (Trouble etc.)
Function
Used to cancel excluding the self-diag U2/PF troubles.
(Purpose)
Item
Trouble
Operation/procedure
1. Press the [START] key.
2. When "1: YES" is selected, troubles other than U2 and PF are can-
celed. (When "2: NO" is selected, the simulation is canceled.)
Default
18
18
18-76
50
50
Error
MX-M260/M310/M260N/M310N SIMULATION 6 - 12
16
16-0
Purpose
Clear/Cancel (Trouble etc.)
Function (Purpose)
Used to cancel the self-diag U2 trouble.
Item
Trouble
Operation/procedure
1. Press the [START] key.
2. When "1: YES" is selected, U2 trouble is canceled.
(When "2: NO" is selected, the simulation is canceled.)
17
17-0
Purpose
Cancel (Trouble, etc)
Function (Purpose)
Used to cancel the self diag "PF" trouble.
Item
Trouble
Operation/Procedure
1. Press the [START] key.
2. When "1: YES" is selected, PF trouble is canceled. (When "2: NO"
is selected, the simulation is canceled.)
21
21-1
Purpose
Setting
Function (Purpose)
Used to set the maintenance cycle.
Item
Specifications
Operation/procedure
1. Enter the set value with the 10-key.
2. Press the [START] key.
Content
Item
26cpm
0
5K
5K
1
10K
10K
2
20K
50K
3
25K
75K
4
50K
100K
5
75K (Default)
150K (Default) *
6
FREE
FREE
* When selecting 150K, maintenance message is displayed by imple-
menting the following conditions.
• Maintenance count = 150K.
• DV count = 100K
• DR count = 100K
* When maintenance message is displayed, replace consumption part
reaching the number of sheets of maintenance, then clear the
replaced part's counter only.
Error
Error
Counter
31cpm