The following is the procedure for changing the settings on DIP switch No. 3.
(1) Turn off the printer and all components connected to it.
(2) Remove the 2 screws.
(3) Remove the serial interface board unit.
(4) Change the setting of the DIP switches.
DIP-SW 3
(5) Replace the serial interface board unit.
(6) Then secure it with the screws.
(7) Turn on the printer and all components connected to it.
The factory settings of DIP switch are all on, except for switches 7 and 8.
Switch
3-1
3-2
3-3
3-4
3-5
3-6
3-7
Should not be changed (Should be set to off)
3-8
Baud Rate
4800BPS
9600BPS
19200BPS
38400BPS
DIP-SW 3
Function
Baud Rate
Data Length
Parity Check
Parity
Handshake
Switch 3-1
– 60 –
ON
8 bits
Disabled
Odd
DTR/DSR
OFF
ON
ON
OFF
ON
OFF
No. 1 2 3 4 5 6 7 8
DIP-SW 3
See table below
Enabled
XON/XOFF
Switch 3-2
ON
ON
OFF
OFF
OFF
7 bits
Even