Environmental Requirements - Star HSP7000 SERIES Hardware Manual

Hybrid printer
Hide thumbs Also See for HSP7000 SERIES:
Table of Contents

Advertisement

10-6-3. Power Connector Pin Layout
Pin No.
1
Drive power (24 V)
2
3
Shell
Note:
• The optional AC adapter (PS60A-24B) has been designed specifically for this unit
(HSP7000).
Other AC adapters may not meet the EMC technical standards.
When using other AC adapters, be sure that the following cautions are observed when
preparing the user's power supply.
• When using a printer power supply other than the optional AC adapter (PS60A-24B
series), be sure that the following cautions are observed.
• Use a power supply of DC 24 V ± 10% and more than 2.0 A (5.0 A Load 10 sec. Min.)
with SELV output and LPS or Class 2 (double-insulation structure) output approved
by IEC60950.
• Be careful about installing the printer in an area where there is noise. Take the ap-
propriate measures to protect against electrostatic AC line noise, etc.

10-7. Environmental Requirements

(1) Operating
Temperature
Humidity
Function
Signal GND
N.C.
Frame ground
5°C to 45°C
10% to 90% RH (without condensation)
(%RH)
90
80
60
40
20
10
0
Operating temperature and humidity range
<Viewed from Connector Surface>
Operating environment
range
10
20
30
Temperature (°C)
– 54 –
1
3
2
34°C 90% RH
40°C 65% RH
45°C 50% RH
40
50

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents