KNTIMER n
default 15
If there is no activity (data) on a KA-Node circuit for n minutes, the KA-Node will
disconnect both the input and output sides of the KA-Node circuit. Setting KNTIMER to
0 disables this feature.
See also: rnrtime
LCOK {ON | OFF}
default ON
When ON, no character translation occurs in the TNC. If OFF, lower case characters
will be translated to upper case before being output to the terminal from the TNC. This
case translation is disabled in Packet Transparent Mode.
LEDS {ON | OFF}
default ON
To conserve power, disable the indicators (LEDS) on the front-panel of the KPC-3 Plus
by setting LEDS to OFF.
LFADD {ON | OFF}
default OFF
When ON, a line-feed will be appended to every carriage return received from the
keyboard before being transmitted. When OFF, no line feeds will be added to the
transmitted signal.
LFSUP {ON | OFF}
default OFF
When ON, this command suppresses any line-feed characters received from the other
station, relying on your terminal program to properly advance to the next line. When
OFF, the line-feeds received from the other station are not suppressed but are sent to
your terminal as received.
See also: autolf, crsup
LGETCHAR $xx
Default $05 (CTRL-E)