speed up the clock. Each count corresponds to 0.64 seconds increase or decrease per
24 hours. Ambient temperature will affect the clock to some degree.
DAYTWEAK has no effect on the (optional) battery-backed clock (BBC); that clock is set
only by using the DAYTIME command. The software clock stops when a soft reset or
powering off occurs, and upon power on the software clock is set to the value of the
BBC, if installed.
See also: wefax
DBLDISC {ON | OFF}
default OFF
When OFF, only one disconnect command (D) need be given to terminate an
unsuccessful connect attempt. If you are actually connected, the normal disconnect
sequence will occur.
When ON, a normal disconnect sequence will always occur (you will not be
disconnected until you receive an acknowledge of your disconnect or until the retry
count is exceeded). A second D is required to force a local disconnect independent of
the retry counter.
See also: disconnect
DELETE n
default $08 <Ctrl+H>
This command sets the character to be used as the delete character. When this
character is typed, the last input character is deleted. The most common settings are
$08 (backspace) and $7F (delete).
See also: bkondel
DIGIPEAT {ON | OFF | UIONLY}
default ON
When ON, any packet received that has MYCALL, MYALIAS, or MYNODE (if KA-Node
is active) in the digipeat list of its address field will be retransmitted. Each station
included in the digipeat list relays the packet in the order specified in the address field.
Digipeating takes place concurrently with other TNC operations and does not interfere
with normal connected operation of the station. To disable digipeat operations (via
MYCALL, MYALIAS, or MYNODE) turn this command OFF.
If UIONLY is selected, the KPC-3 Plus will digipeat UI frames only.
See also: hid, myalias, mycall, mynode