3.3 Errors That Require a Service Technician

MAINTENANCE CALL 0100

"
Problem
The waste ink pads are almost full, causing a warning error. The
printer can continue printing, but this messages overrides status
messages such as Ready or Printing.
"
Solution
Replace the following parts and reset the counters as described below
!
Waste Ink Pads
!
F Box
!
Pump Assembly
!
Cap Assembly
!
Cleaner, Head
!
From Maintenance Mode 2 enter the Counter Init. Menu and initialize
the Waste Ink counter and Cleaning counter.

SERVICE CALL 00000100

"
Problem
The waste ink pads are completely full, causing a fatal error. The
printer stops printing.
"
Solution
Replace the following parts and reset the counters as described below
!
Waste Ink Pads
!
F Box
!
Pump Assembly
!
Cap Assembly
!
Cleaner, Head
!
From Maintenance Mode 2 enter the Counter Init. Menu and initialize
the Waste Ink counter and Cleaning counter.
Troubleshooting

SERVICE CALL 00000101

"
Problem
A printer part has exceeded its useful life, and to prevent damage to
other parts as well as abnormal operations/printouts, an error occurs.
This error occurs when the CR Motor has reached 2.5 million passes,
and this indicates the ink tubes should be replaced due to excessive
wear and tear.
"
Solution
To make sure the ink tubes are not worn out, verify no part of any of
the tubes shows wear, is loose, or leaks ink anywhere, especially the
tube area between the printheads and the ink pipes.

SERVICE CALL 00010000

"
Problem

PF motor encoder check error

The PF motor makes small revolutions clockwise and counter-
clockwise. When it turns, the printer checks the rotary encoder output
signals to make sure the motor is turning at the correct speed/
distance. If there the encoder doesn't send the correct signal or output
data, an error occurs.
"
Solution
Make sure there is nothing blocking the grid rollers. If that does not
solve the problem, check the PF motor encoder connection. If there
still is a problem, try the following.
!
!
!
Errors That Require a Service Technician
Check and adjust the PF Belt tension
Replace the PF motor