Blocked Vent Shutoff System

Installation
This appliance is equipped with a blocked vent shutoff
system. The switch assembly is shipped with the appliance.
1) Unravel wire, feed through front grommeted hole located
on the firebox support and right hand casing side.
2) Connect wire to "TPTH" and "TH" terminals on the gas
valve (Fig. #10).
3) Remove the two screws located at the uppermost right
front corner of the appliance.
4) Position the spill switch over the two holes and fasten in
place with the two screws (Fig. #9).
5) Install surround assembly. Connect remaining wire leads
to the rocker switch on the surround trim.
Fig. # 9
Fig. # 10
Thermopile
8

Draft Inspection

This appliance must be connected to a venting system with
adequate draft to ensure safe and proper operation.
To inspect vent operation:
A few minutes after the appliance is lit, insert a smoke stick
between the middle and top louver (Fig. #11). If the smoke is
drawn in, the venting system is operating properly. If the
smoke is not drawn into the opening, turn the unit off and
inspect the venting system for blockages or restrictions.
Fig. # 11
Rocker Switch
Smoke Stick
Spill Switch
Gas Valve