IMPORTANT: When lit for the first time, the
appliance will emit a slight odor for a couple of
hours. This is due to the curing of paints, seal-
ants and lubricants used in the manufacturing
process. This condition is temporary. Open doors
and windows to ventilate area. If optional fan kit
has been installed, place fan in the "OFF" posi-
tion. Smoke and fumes caused by the curing
process may cause discomfort to some individu-
als.
It is normal for fireplaces fabricated of steel to
give off some expansion and/or contraction
noises during the start up or cool down cycle.
Similar noises are found with your furnace heat
exchanger or cook stove oven.
Fig. # 1
Standard-size Surround Assembly, Plain and Embossed Bevelled Panels ............ 38 1/2" wide x 27 1/4" high
Over-size Surround Assembly, Plain Flat Panels ................................................... 44 3/4" wide x 30 1/2" high
2 7
B
1 2 1
/ 2 "

Caution

FOR YOUR SAFETY - Do not install or operate your
Pacific Energy Brentwood Gas Insert without first reading
and understanding this manual. Any installation or opera-
tional deviation from the following instructions voids the
Pacific Energy Gas Stove Warranty and may prove hazard-
ous.
This appliance and its individual shutoff valve must be
disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of 1/
2 psig (3.5 kPa).
This appliance must be isolated from the gas supply piping
system by closing its individual manual shutoff valve during
any pressure testing of the gas supply piping system at test
pressures equal to or less than 1/2 psig (3.5 kPa).