VENT TERMINAL INSTALLATION

NOTE: THE VENT TERMINAL MUST BE POSITIONED SO THAT
THE FLUE OUTLET IS POINTING UP.
1) Install the vent terminal backing plate on the outside wall. (see
Fig. #14) When placing the backing plate, make sure the 7" collar
inserts into the corresponding vent pipe. Attach backing plate to
the outside wall with screws at each corner. Fasten the vent pipe
in place with sheet metal screws through the holes provided in the
collar.
2) Attach vent terminal box to the backing plate with screws pro-
vided. Make sure the 5" collar inserts into the corresponding vent
pipe.
3) Caulk in place to prevent any moisture entering the structure.
MINIMUM CLEARANCES TO THE VENT TERMINAL MUST BE
MAINTAINED. (SEE FIG. # 13)
NOTE: LOCAL CODES OR REGULATIONS MAY REQUIRE DIF-
FERENT CLEARANCES.
Fig # 13
12
Fig. # 14
VENT TERMINAL MINIMUM
CLEARANCES