IMPORTANT:
KEEP THESE INSTRUCTIONS FOR
FUTURE REFERENCE.

INSTALLATION AND OPERATING INSTRUCTIONS

If this stove is not properly installed, a house fire may result. For your safety, follow the
installation instructions. Contact local building or fire officials about restrictions and
©PACIFIC ENERGY FIREPLACE
110515-24
PRODUCTS LTD. - 2015
NEO 2.5 Insert
- AUSTRALIA

SAFETY NOTICE

installation inspection requirements in your area.
MODEL: NEO2.5 INSERT
NE25.ASINS
SERIAL #
5055.950AS

Advertisement

Table of Contents
loading

Summary of Contents for Pacific energy NEO2.5 INSERT

  • Page 1: Installation And Operating Instructions

    If this stove is not properly installed, a house fire may result. For your safety, follow the installation instructions. Contact local building or fire officials about restrictions and installation inspection requirements in your area. MODEL: NEO2.5 INSERT ©PACIFIC ENERGY FIREPLACE 110515-24 NE25.ASINS...
  • Page 2: Table Of Contents

    Contents General Safety ............. 3 Maintenance Checks............ 4 Creosote ..............5 Formation and Need for Removal ......5 In the event of a Chimney Fire ......5 Operation ..............6 Wood Selection ............ 6 How to Test Your Wood ........6 Lighting the Fire ...........
  • Page 3: General Safety

    This will also create heavy deposit build-up in the chimney. 4. DOOR GASKET - The gasket used by Pacific Energy (22mm medium density fiberglass WARNING: rope) requires only light pressure to seal.
  • Page 4: Maintenance Checks

    Maintenance Checks Check the following parts for damage such as cracks, excessive corrosion, burned out sections and excessive warping: (See website for descriptions and more detail) Weekly: - Firebrick - Visual, for cracking. - Door Gasket - sagging, placement, damage. Monthly - Brick rail tabs and brick rails.
  • Page 5: Creosote

    Creosote Formation and Need for Removal When wood is burned slowly, it produces tar and other organic vapours, which combine with expelled moisture to form creosote. The creosote vapours condense in the relatively cool chimney flue of a slow burning fire. As a result, creosote residue accumulates on the flue lining.
  • Page 6: Operation

    5) Begin normal operation after a good coal base exists and wood has charred. Your Pacific Energy heater is designed for maximum overall efficiency at a moderate WARNING: Do not use grates or firing rate. Overfiring is hazardous and a waste of fuel. Too slow a burn contributes to andirons to elevate the fuel.
  • Page 7: Normal Operation

    Normal Operation WARNING: Always keep loading 1) To refuel, adjust air control to “H” (high) position (pushed to the far left) and give the fire time to brighten. Open door slowly, this will prevent smoke from rolling out. door closed when burning, exept as instructed during start-up.
  • Page 8 Dimensions fig# 1 1.2m 1.02m 838mm 667mm 813mm 725mm 724mm 552mm 368mm 546mm 556mm 502mm 606mm 838mm 1020mm MINIMUM FIREPLACE OPENING AND HEARTH DIMENSIONS fig#2 NON COMBUSTIBLE HEARTH 680mm MUST EXTEND OUT 500MM FROM THE LOADING DOOR 560mm OPENING. 510mm 870mm 50mm 50mm...
  • Page 9: Minimum Clearances

    Minimum Clearances Fig# 3 Minimum Clearances to Combustibles (Measured From Top of Brow) A: Mantel ............405mm B: Mantel Key ..........390mm (Measured from Side of Door) C: Mantel Upright ........150mm D: Adjacent Sidewall ......380mm E: Hearth Width........872mm (Measured from Front of Appliance Base) F: Hearth Depth........500mm ZERO CLEARANCE Ember protection:...
  • Page 10: Masonry Fireplace Installation

    Masonry Fireplace Installation WARNING: UNDER NO CIRCUMSTANCES IS THIS HEATER TO BE INSTALLED IN A MAKESHIFT OR “TEMPORARY” MANNER. IT MAY BE FIRED ONLY AFTER THE STOVE IS INSTALLED PROPERLY. WARNING: THE APPLIANCE AND FLUE-SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH AS/ NZS 2918 AND THE APPROPRIATE REQUIRMENTS OF THE RELEVANT BUILDING CODE OR CODES WARNING: APPLIANCES INSTALLED IN ACCORDANCE WITH THIS STANDARD SHALL COMPLY WITH THE REQUIREMENTS OF AS/NZS 4013 WHERE REQUIRED BY THE REGULATORY AUTHORITY, I.E.
  • Page 11: Full Flue Liner

    Full Flue Liner This fireplace insert must be installed with a continuous liner of 150mm diameter extending from the fireplace insert to the top of the chimney. Measure the chimney height from the top of the existing flue to the floor of the hearth. The services of a competent or This will allow extra length of liner for flashing and rain cap.
  • Page 12: Chimney And Connector

    Chimney and Connector WARNING: INSTALL CHIMNEY AND ALL COMPONENTS OF CHIMNEY SYSTEM ACCORDING TO CHIMNEY MANUFACTURER’S INSTRUCTIONS. Connect to a listed chimney complying with the requirements of AS/NZS2918/2001 and a chimney suitable for use with solid fuel that is lined and in good condition and meets local building codes. The chimney flue size should be the same as the stove outlet for optimal performance.
  • Page 13: Firebrick Installation

    Firebrick Installation This package contains 14 full-size firebricks. With the heater in the upright position, install firebricks as follows: - First, install 4 firebricks against the rear wall. - Next, install the side firebricks, 3 each side. - Lastly, place 4 firebricks on the bottom of the heater. ARTICLE NUMÉRO DE PIÈCE ITEM/...
  • Page 14: Combustion Air

    Combustion Air Consult local building codes regarding combustion air supply. Intake or combustion air can be supplied to the Insert in one of two ways: Outside air supply: Remove cover from ash clean out in existing fireplace. Place a rodent screen in place of the cover.
  • Page 15: Blower Operation

    Blower Operation The Insert comes equipped with circulating air blowers. The blower system is thermostatically controlled for automatic operation, as well manually with a convenient bypass switch. Automatic: To operate the blower automatically, push the rocker switch to the “0” or AUTO position and set the fan speed control to a desired setting.
  • Page 16: Cleaning/Maintenance

    Cleaning/Maintenance Ash Removal Whenever ashes get above 75mm deep in your firebox, and when the fire has burned down WARNING: DO NOT OPERATE and cooled, remove excess ashes. Leave an ash bed approximately 30mm deep on the firebox WITH BAFFLE ASSEMBLY OR bottom to help maintain a hot charcoal bed.
  • Page 17: Blower Replacement

    Blower Replacement Fig# 9 Remove the front trim by lifting and pulling away from the unit. Remove the four screws securing the back plate to the brackets and set them aside carefully to avoid damage. 2. Remove the Back plate mounting bracket by removing the two screws securing the bracket to the side casing of the unit.
  • Page 18: Power Cord Position

    Power Cord Position Fig. # 12 he power cord for the NEO 2.5 Insert comes factory set to exit the right side of the unit. If you desire, the cord can be switched to exit to the left of the unit. The cord will lose approximately 12”...
  • Page 19 5055.950AS 110515-24 NE25.ASINS...
  • Page 20: Troubleshooting

    Troubleshooting Problem Cause Cure Excessive Creosote Wood is too wet - Use dry wood Buildup Turning down air control - Do not turn down until: too soon a) there is a good bed of coals b) the wood is charred Draft too low - Improper chimney height and/or diameter - Chimney plugged or restricted, check flue...
  • Page 21: Parts List

    Parts List ITEM DESCRIPTION PART NO. 1 ..Top Casing ..................7863.5 2 ..Side Casing, LHS ................7861 3 ..Side Casing, RHS ................7861.5 4 ..Blower Assembly, LHS ..........NE25.502453 Blower Assembly, RHS NE25.502454 6 ..Gasket Guide/Glass Retainer set .........NE25.7840 7 ..
  • Page 22 5055.950AS 110515-24 NE25.ASINS...
  • Page 23: Rating Label

    Rating Label NEO 2.5 INSERT Tested by: HRL TECHNOLOGY PTY LTD TRAMWAY ROAD, MORWELL, VICTORIA HCMG/15/007 24/FEB/2015 WHEN TESTED IN ACCORDANCE WITH: AS/NZS 4012:2014 & AS/NZS4013:2014 MAXIMUM AVERAGE HEAT OUTPUT BURNING HARDWOOD 9.2 kW OVERALL AVERAGE EFFICIENCY BURNING HARDWOOD PARTICULATE EMISSIONS FACTOR - 1.0g/kg CATALYTIC COMBUSTOR - NO Distributed by: PIVOT STOVES AND HEATING CO 234-238 MOORABOOL STREET, GEELONG, VIC 3220...
  • Page 24 © 2015 Copyright Pacific Energy Fireplace Products LTD Reproduction, adaptation, or translation without prior written permission is prohibited, except as allowed under the copyright laws. PACIFIC ENERGY FIREPLACE PRODUCTS LTD. www.pacificenergy.net 2975 Allenby Rd., Duncan, B.C. V9L 6V8 Printed in Canada...