Installation - Pacific energy Brentwood Gas Insert Installation And Operating Instructions Manual

Series a vented gas fireplace heater
Table of Contents

Advertisement

Installation

Caution: A gas appliance must NOT be connected to a
chimney flue servicing a separate solid fuel burning appli-
ance.
This appliance MUST be properly connected to a venting
system. This heater is equipped with a blocked vent
shutoff system designed to protect against improper vent-
ing of combustion products.
WARNING: Operation of this heater when not connected to
a properly installed and maintained venting system or tam-
pering with the blocked vent shutoff system can result in
carbon monoxide (CO) poisoning and possible death.
Note: This appliance has a draft hood built in, and when
installed according to these instructions, the draft hood is in
the same atmospheric pressure zone as the combustion air
inlet to the appliance. Adequate combustion and ventilation
air must be provided for safe and proper operation.
The Brentwood Insert installation and venting must con-
form to the current CAN/CGA-B149 installation code (in
Canada) or the National Fuel Gas Code, ANSI Z223.1 -
1988 (in the USA), and approved per local codes. Only
qualified (licensed or trained) personnel should install
this product.
Only listed trim kits shall be used in the installation of this
appliance. Draft Relief Openings must not be covered or
blocked.
Existing Fireplace
(Masonry or Factory Built)
In order to sufficiently accommodate the Brentwood Insert,
the minimum size of the fireplace should be 28 inches wide,
21 inches high and 13 inches deep (Fig. #3).
Fig. # 3
13"
21"
MINIMUM
MINIMUM
Fig. # 4
32 1/2"
32"
The fireplace and its chimney should be swept and inspected.
The existing fireplace damper (if present) should be locked
open or removed completely if opening is too small for a 4"
flue liner to pass through.
Optional Zero Clearance Kit
The Brentwood Insert may be framed in with the optional
Mirage Zero-Clearance Kit (Fig. #4). Refer to the installation
instructions that are supplied with the kit for framing dimen-
sions and precautions. This unit must not be installed with
zero clearance to combustible material without the use of the
kit.
28"
MINIMUM
17"
5