Pacific energy Alderlea T5 Insert Installation And Operating Instructions Manual

Pacific energy Alderlea T5 Insert Installation And Operating Instructions Manual

Advertisement

IMPORTANT:
KEEP THESE INSTRUCTIONS
FOR FUTURE REFERENCE.
INSTALLATION AND OPERATING
If this stove is not properly installed, a house fi re may result. For your safety,
follow the installation instructions. Contact local building or fi re officials about
restrictions and installation inspection requirements in your area.
©PACIFIC ENERGY FIREPLACE
150714-24
PRODUCTS LTD. - 2014
Alderlea T5 Insert,
T5 Classic Insert
INSTRUCTIONS

SAFETY NOTICE

MODEL: ALT5 INSERT
SERIES - D
ALT5.ASCINSB
5055.203-BAS

Advertisement

Table of Contents
loading

Summary of Contents for Pacific energy Alderlea T5 Insert

  • Page 1: Safety Notice

    IMPORTANT: KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE. Alderlea T5 Insert, T5 Classic Insert INSTALLATION AND OPERATING INSTRUCTIONS SAFETY NOTICE If this stove is not properly installed, a house fi re may result. For your safety, follow the installation instructions. Contact local building or fi re officials about restrictions and installation inspection requirements in your area.
  • Page 2: Table Of Contents

    Fan Removal/Installation ............16 Surround Assembly and Installation ........... 18 Replacement Parts, Alderlea T5 ............19 Replacement Parts, Alderlea T5 Classic ..........20 Troubleshooting ................21 Firebrick Installation ................22 Label ..................23 ©PACIFIC ENERGY FIREPLACE ALT5.ASCINSB 150714-24 PRODUCTS LTD.
  • Page 3: Maintenance Checks

    - Please contact your Dealer if you experience any of the damage listed above. Continuing to operate your stove with broken parts may accelerate damage to other parts and may void your warranty ©PACIFIC ENERGY FIREPLACE ALT5.ASCINSB 150714-24 PRODUCTS LTD.
  • Page 4: Maintenance

    Be careful, as they are very sharp. Install new cleaning the chimney liner. If debris gets into the tube it can glass complete with gasket. Replace clamps and screws. cause the tube to prematurely burn out. ©PACIFIC ENERGY FIREPLACE ALT5.ASCINSB 150714-24 PRODUCTS LTD.
  • Page 5: Creosote

    Chimney fi res are easy to detect; they usually involve one or more of the following: - Flames and sparks shooting out of the top of the chimney - A roaring sound - Vibration of the chimney ©PACIFIC ENERGY FIREPLACE ALT5.ASCINSB 150714-24 PRODUCTS LTD.
  • Page 6: Operation

    Any tampering will void warranty and could be very hazardous. Do not store/place wood or other combustibles within the required clearances surrounding the unit. Air Control set to low. ©PACIFIC ENERGY FIREPLACE ALT5.ASCINSB 150714-24 PRODUCTS LTD.
  • Page 7: Restarting After Extended Or Overnight Burns

    If the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retained in the closed container until all cinders have thoroughly cooled. Other waste should not be placed in this container! ©PACIFIC ENERGY FIREPLACE ALT5.ASCINSB 150714-24 PRODUCTS LTD.
  • Page 8: Safety

    Keep children, clothing and furniture away. Contact may cause skins burns. Fig. # 1 Mantel or Top Facing 600mm 300mm 300mm e n t j a c Fireplace Hearth 51mm ©PACIFIC ENERGY FIREPLACE ALT5.ASCINSB 150714-24 PRODUCTS LTD.
  • Page 9 Combustible fl oor in front of the fi replace insert must be protected from hot embers by non-combustible material extending 400mm to the fi ring side from the door and 200mm to other sides of the unit. MINIMUM EMBER PROTECTION DIMENSIONS 572mm 400mm Non-combustible fi replace hearth Non-combustible fl oor covering 51mm ©PACIFIC ENERGY FIREPLACE ALT5.ASCINSB 150714-24 PRODUCTS LTD.
  • Page 10: Dimensions

    Dimensions ALT5 INSERT & ALT5 CLASSIC INSERT WITH REGULAR SURROUND WITH OVERSIZED SURROUND 867mm 772mm 746mm 841mm 1.08m 1.08m 448mm 241mm 530mm 546mm 448mm 270mm 606mm 721mm 854mm ©PACIFIC ENERGY FIREPLACE ALT5.ASCINSB 150714-24 PRODUCTS LTD.
  • Page 11: Installation

    OPERATED AT ALL TIMES IN ACCORDANCE WITH THESE IN- STRUCTIONS. CAUTION: THE USE OF SOME TYPES OF PRESEVATIVE-TREATED WOOD AS A FUEL CAN BE HAZARDOUS. DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVICING ANOTHER APPLIANCE. ©PACIFIC ENERGY FIREPLACE ALT5.ASCINSB 150714-24 PRODUCTS LTD.
  • Page 12: Full Flue Liner (Fig #2)

    8) Attach a rain cap to the end of the liner. A storm collar should be used. (Follow vent manufacturers instructions.) Combustion Air Consult local building codes regarding combustion air supply. Intake or combustion air can be supplied to the Insert in one of ©PACIFIC ENERGY FIREPLACE ALT5.ASCINSB 150714-24 PRODUCTS LTD.
  • Page 13: Chimney And Connector

    See Combustion Air section on page 12.) 2. Installed with the crimped or male ends pointing down. This will carry any liquid creosote or condensation back into the stove. ©PACIFIC ENERGY FIREPLACE ALT5.ASCINSB 150714-24 PRODUCTS LTD.
  • Page 14: Fan Speed Controller Relocation

    The fan speed controller is factory installed under the ash lip space and possibly cause suffocation. on the right hand side. If required, it can be relocated to the left Fig. # 5 Fig. # 7 O/A Cover Screw Remove Knockout ©PACIFIC ENERGY FIREPLACE ALT5.ASCINSB 150714-24 PRODUCTS LTD.
  • Page 15 7) Install fan shield as shown in Fig. #13. Be sure to place the Fig. # 8 Fig. # 11 air inlet opening against the surround side. 8) Install the cast decorative top by tilting it at a slight angle, Fig. # 12 Fig. # 9 ©PACIFIC ENERGY FIREPLACE ALT5.ASCINSB 150714-24 PRODUCTS LTD.
  • Page 16: Fan Removal/Installation

    3) Remove the two screws securing the fan bracket to the stove using a 7/16” socket or wrench. Reverse steps 1&2 to install new fan.(Fig #17) Fig. # 14 Fig. # 16 Fig. # 17 SCREWS THERMAL SWITCH ©PACIFIC ENERGY FIREPLACE ALT5.ASCINSB 150714-24 PRODUCTS LTD.
  • Page 17 (Fig #25). Use the upper screw holes for best SCREWS alignment. 4) Loosen the two bolts that secure the ash lip to the fi rebox (Fig #22), carefully lift up the ash lip and remove from the fi rebox. ©PACIFIC ENERGY FIREPLACE ALT5.ASCINSB 150714-24 PRODUCTS LTD.
  • Page 18: Surround Assembly And Installation

    (Fig #30). Wire placement Fig. # 26 WIRE SUPPORT TABS Fig. # 29 THERMAL SWITCH Fig. # 27 Fig. # 30 ©PACIFIC ENERGY FIREPLACE ALT5.ASCINSB 150714-24 PRODUCTS LTD.
  • Page 19: Replacement Parts, Alderlea T5

    Contact Pacifi c Energy for the location of the dealer ....Ashlip Assy, Black Enamel ..ALT5.P50274723BK nearest you....Ashlip Assy, Majolica Brown Enamel ........ALT5.P50374723BN 7....Door Catch ............ 4740 NOT SHOWN Fig. # 33 ©PACIFIC ENERGY FIREPLACE ALT5.ASCINSB 150714-24 PRODUCTS LTD.
  • Page 20: Replacement Parts, Alderlea T5 Classic

    19 ..Blower (RHS) ..........5024.54 ....ALT5.P50374723BN ....Blower (LHS) ..........5024.53 7....Door Catch ............ 4740 20..Blower Mounting Bracket ....... 4541 21..Control Box Assembly ......SPND.4583 22..Crown Assembly, Black ..ALT5.P50374724BK ....Crown Assembly, Brown ..ALT5.P50374724BN NOT SHOWN Fig. # 34 ©PACIFIC ENERGY FIREPLACE ALT5.ASCINSB 150714-24 PRODUCTS LTD.
  • Page 21: Troubleshooting

    - Check outside air supply for obstructions is blocked (see Combustion Air section) 2) Draft too low - Chimney plugged or restricted Inspect and clean - Chimney oversized or otherwise unsuitable Consult Dealer ©PACIFIC ENERGY FIREPLACE ALT5.ASCINSB 150714-24 PRODUCTS LTD.
  • Page 22: Firebrick Installation

    Firebrick Installation Alderlea T5 Insert This package contains 18 full-size fi rebricks, as well as 1 cut-size brick. With the heater in the upright position, install fi rebricks as follows: - Place fi rebricks on the bottom of the heater fi rst. Total of 7 full-size and 1cut brick.
  • Page 23: Label

    Label PACIFIC ENERGY FIREPLACE PRODUCTS LTD. 2975 ALLENBY RD., DUNCAN, BC V9L 6V8 Model: ALDERLEA T5 Series: D Type: FIREPLACE INSERT Tested by: HRL TECHNOLOGY PTY LTD TRAMWAY ROAD, MORWELL, VICTORIA Tested to: AS/NZS 4013:1999 Test report no: HCMG/13/048 1/OCT/2013 MAXIMUM AVERAGE HEAT OUTPUT BURNING HARDWOOD - 10.0 kW...
  • Page 24 PACIFIC ENERGY FIREPLACE PRODUCTS LTD. www.pacifi cenergy.net Technical Support: 1-250-748-1184 2975 Allenby Rd., Duncan, B.C. V9L 6V8 Printed in Canada ©PACIFIC ENERGY FIREPLACE PRODUCTS LTD.

This manual is also suitable for:

T5 classic insertAlderlea t5Alderlea t5 classic

Table of Contents