Connecting the PSTN Fallback Port

The Fallback feature uses identical cabling as the normal ports. The PSTN fallback port
allocation depends on the MediaPack model:
MP-404 /BRI /ST /AC /FB: ports 0 and 1 are interconnected if the gateway is not
powered
MP-408 /BRI /ST /AC /FB: ports 0 and 1, and ports 2 and 3 are interconnected if the
gateway is not powered

Figure 3-12: Fallback Cabling (MP-404 /BRI /ST /AC /FB and MP-408 /BRI /ST /AC /FB)

Warning:
Notes:
User's Manual
If Fallback is activated on two ports that are configured as user side,
damage can be caused to external equipment. Ports 2 and 0 must be
configured as Point to Point, User side interfaces. For additional
information on configuring the ISDN ports, refer to Chapter 6.
If ports 0 and 1, and ports 2 and 3 are configured identically (both user
and both net side), Fallback does not function.
If ports 0 and 1, or ports 2 and 3 are configured as user side (i.e.,
connected to systems that provide power), Fallback does not function
and the external equipment can be damaged.
The MediaPack is protected against such invalid configurations as
described above.