MAINTENANCE

FAN MAINTENANCE

If your fan requires maintenance or replace-
ment, access to the fan is through the rear
access panel on the back of the unit. NOTE:
the unit MUST NOT be operated without
the fan access panel securely in place and
correctly sealed.
IMPORTANT: These fans collect a lot of
dust from within your home. Ensure you
maintain these fan motors on a regular basis
by vacuuming out the fan squirrel cages,
around the motor, and around the grills on
the back of the stove.
WARNING:
Electrical Grounding Instructions
This appliance is equipped with
a three pronged (grounding) plug
for your protection against shock
hazard and should be plugged
directly into a properly grounded
three-prong receptacle. Do not cut
or remove the grounding prong
from this plug.
IMPORTANT
Disconnect power supply
before servicing
34
To Remove Fan:
1) Unplug or disconnect power source to
stove.
2) Remove the 6 screws holding the access
panel in place.
3) Unclip the black, violet and white wires from
the fan motor.
4) Lift fan off of the 2 pins, tip back and pull
through rear panel. Do not tear or damage the
fl ex pipe when removing the fan. Disconnect
the green ground wire from the right side of
the fan as soon as you can reach it.
Replacing the Fan:
Reverse steps 4 thru 1. Make sure the fan wires
and the ground wire are reattached.
Hint for pushing fan down onto pins - rub a
bit of dish soap on the grommet so it will slide
more easily onto the pin. Check to make sure
the fan is seated properly on the pins - try to
move the fan back and forth, there should be
no noise, if there is check that the grommets
haven't come loose.