General Vent Maintenance; Log Replacement; Electrical Grounding Instructions; Glass Replacement - HAMPTON BAY H35-10 Owners & Installation Manual

Table of Contents

Advertisement

GENERAL VENT
MAINTENANCE
Conduct an inspection of the venting system semi-
annually. Recommended areas to inspect as follows:
1) Check the Venting System for corrosion in areas
that are exposed to the elements. These will
appear as rust spots or streaks, and in extreme
cases, holes. These components should be
replaced immediately.
2) Remove the Cap, and shine a flashlight down the
Vent. Remove any bird nests, or other foreign
material.
3) Check for evidences of excessive condensa-
tion, such as water droplets forming in the inner
liner, and subsequently dripping out the joints,
Continuous condensation can cause corrosion
of caps, pipe, and fittings. It may be caused by
having excessive lateral runs, too many elbows,
and exterior portions of the system being ex-
posed to cold weather.
4) Inspect joints, to verify that no pipe sections or
fittings have been disturbed, and consequently
loosened. Also check mechanical supports such
as Wall Straps, or plumbers' tape for rigidity.

LOG REPLACEMENT

The unit should never be used with broken logs. Turn
off the gas valve and allow the unit to cool before
opening door to carefully remove the logs. The pilot
light generates enough heat to burn someone. If for
any reason a log should need replacement, you
must use the proper replacement log. The position
of these logs must be as shown in the diagram
under Log Installation.
Note: Improper positioning of logs may create
carbon build-up and will alter the unit's
performance which is not covered under
warranty.

GLASS REPLACEMENT

Your stove is supplied with high temperature, 5
mm Neoceram ceramic glass that will withstand
the highest heat that your unit will produce. In the
event that you break your glass by impact, purchase
your replacement door from an authorized Hampton
dealer only, and follow our step-by-step instructions
for replacement.
1) Lift off the Cast Top.
2) Open the 2 latches of the Glass Front.
3) Lift the Glass Front Assembly up.
Latches
4) Remove the glass and replace with the new
glass.
5) Replace the door and Cast Top.
Replacement Part # 940-324/P Glass
®
WARNING: Do not operate appliance
with glass panel removed, cracked
or broken. Replacement of the glass
should be done by a licensed or quali-
fied service person.
Note: Wearing gloves will protect your hands
while handling glass.
maintenance

FAN MAINTENANCE

If your fan requires maintenance or replacement,
access to the fan is through the rear access panel
on the back of the unit. NOTE: the unit MUST
NOT be operated without the fan access panel
securely in place and correctly sealed.
IMPORTANT: These fans collect a lot of dust
from within your home. Ensure you maintain
these fan motors on a regular basis by vacuum-
ing out the fan squirrel cages, around the motor,
and around the grills on the back of the stove.

Electrical Grounding Instructions

This appliance is equipped with
a three pronged (grounding) plug
for your protection against shock
hazard and should be plugged
directly into a properly grounded
three-prong receptacle. Do not cut
or remove the grounding prong
from this plug.
Disconnect power supply
before servicing
To remove fan:
1) Unplug or disconnect power source to stove.
2) Remove the 6 screws holding the access panel
in place.
3) Unclip the black and red wires from the fan
motor.
4) Lift fan off of the 2 pins, tip back and pull through
rear panel. Do not tear or damage the flex pipe
when removing the fan. Disconnect the green
ground lug wire from the fan as soon as you
can reach it.
Hampton® H35-10 Direct Vent Freestanding Gas Stove
|
43
WARNING:
IMPORTANT
Rear Access Panel
43
|