HAMPTON BAY H27U-NG Owners & Installation Manual
HAMPTON BAY H27U-NG Owners & Installation Manual

HAMPTON BAY H27U-NG Owners & Installation Manual

Direct vent gas fireplace
Table of Contents

Advertisement

Quick Links

H27U-NG/LP Direct Vent Gas Fireplace
MODELS:
H27U-NG Natural Gas
WARNING:
If the information in these instructions are not fol-
lowed exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable
vapours and liquids in the vicinity of this or any
other appliance.
Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
Tested by:
Installer: Please complete the details on the back cover and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
920-416a
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
H27U-LP Propane
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appliance
Do not touch any electrical switch:
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas sup-
plier, call the fire department.
Owners &
Installation Manual
www.hampton-fire.com
This appliance may only be
installed in an aftermarket
permanently located, manu-
factured (USA only) or mobile
home, where not prohibited by
local codes.
This appliance is only for use
with the type of gas indicated
on the rating plate. This ap-
pliance is not convertible for
use with other gases, unless
a certified kit is used.
02.18.22

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the H27U-NG and is the answer not in the manual?

Questions and answers

Summary of Contents for HAMPTON BAY H27U-NG

  • Page 1 Owners & H27U-NG/LP Direct Vent Gas Fireplace Installation Manual www.hampton-fire.com MODELS: H27U-NG Natural Gas H27U-LP Propane WARNING: FOR YOUR SAFETY This appliance may only be If the information in these instructions are not fol- installed in an aftermarket lowed exactly, a fire or explosion may result causing...
  • Page 2 You are the owner of a state-of-the-art Hampton ® Gas Stove by REGENCY FIREPLACE PRODUCTS. The H27U-NG/LP is a hand crafted appliance designed to provide you with all the warmth and charm of a wood fireplace at the flick of a switch.
  • Page 3: Table Of Contents

    Cathedral Ceilings ................32 Round Support (RDS) & Square Support (SQS) ......32 Support Extensions - Round (RDSE) or Square (SQSE) ....32 High Elevation ..................32 Gas Connection ................. 32 System Data ..................32 Hampton ® H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove...
  • Page 4: Copy Of Safety Label

    With the panel removed, the gas valve will be visible. *Printer: Start number sequence @ 044000001 The rating plate will be attached to a black chain located under the IFC. DO NOT REMOVE THE DECAL FROM THE UNIT. Hampton ® H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove...
  • Page 5: Unit Dimensions With Vertical Venting

    Unit Dimensions with Horizontal Venting " " 498mm 624mm " 454mm " " 592mm 461mm ALL PICTURES / DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRATION PURPOSES ONLY. ACTUAL PRODUCT MAY VARY DUE TO PRODUCT ENHANCEMENTS. Hampton ® H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove...
  • Page 6: Copy Of The Lighting Plate Instructions

    DO NOT REMOVE THIS INSTRUCTION PLATE NE PAS ENLEVER CETTE ÉTIQUETTE D’INSTRUCTIONS 920-181a Part #: 920-181a Colours: Black on Grey, except for parts indicated as being Red. Hampton ® H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove Punch out .25" hole top right corner where indicated.
  • Page 7 (e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipm ent, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. Hampton ® H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove...
  • Page 8: Gas Installation Checklist

    Does the supply pressure meet the requirements shown on the rating plate? Was a conversion performed? Was a leak check performed and manifold pressures verified? Is the shut-off valve installed and easily accessible to the customer? Hampton ® H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove 05/18/21...
  • Page 9 Are the model and serial numbers and the date of installation of the unit written in the manual and on the checklist? Were the warranty and unit registration reviewed with the customer? Comments: Hampton ® H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove 05/18/21...
  • Page 10: Before You Start

    INDIVIDUAL IN THE HOUSE. TO RESTRICT ACCESS TO A FIREPLACE OR STOVE, INSTALL AN ADJUSTABLE SAFETY GATE TO KEEP TODDLERS, YOUNG CHILDREN AND OTHER AT RISK INDIVIDUALS OUT OF THE ROOM AND AWAY FROM HOT SURFACES. Hampton ® H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove...
  • Page 11: Important Message

    "Manufactured Mobile Home Additional This appliance may only be installed Requirements" section and "Venting Arrange- Fuels: H27U-NG is approved for use with natural in an aftermarket permanently located, ments" section for the required vent arrange- gas. manufactured (USA only) or mobile ments.
  • Page 12: General Safety Information

    First allow the unit to burn for 15-20 min. to stabilize. CAUTION: Any alteration to the product that causes sooting or carboning that results in dam- age is not the responsibility of the manufacturer. Hampton ® H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove...
  • Page 13: Locating Your Gas Stove

    Extra provision for combustion air inside the 9) Connect the ground (green) wire to the gound room is not required. lug on either side of the unit. Nylon Plug Hampton ® H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove...
  • Page 14 This appliance is equipped with a three pronged (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug. Hampton ® H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove...
  • Page 15: Venting Introduction

    1) Wear gloves and safety glasses for protection. in combination with the Direct Vent Freestanding H27U-NG, and H27U-LP. The warranty will be voided Gas Stoves, H27U-NG, and H27U-LP, have been and serious fire, health or other safety hazards may...
  • Page 16: Exterior Vent Terminal Locations

    * Clearance in accordance with local installation codes and the requirements of the gas supplier 3 feet (91cm) within a height of 15 feet (4.5m) above the meter / regulator assembly 3 feet (91cm) above - if within 10 feet (3m) horizontally Hampton ® H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove...
  • Page 17: 4" X 6-5/8" Rigid Pipe Cross Reference Chart

    4DWT SV4RSM VDV-WPT04 Wal l Thimble Cover/Ceiling Support 46DVA-DC SV4PF Firestop Spacer 46DVA-FS 4DT-FS 4DFSP 4DFS SV4BF TM-4CS VDV-FS04 Trim Plate-Black 4DT-TP 4DFPB 4DcP SV4LA TM-4TP VDV-WTC04 * Not available from Regency Hampton ® H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove...
  • Page 18 Note: Horizontal runs of vent must be level, or have a 1/4” rise for every 1 foot of run towards the termination. Never allow the vent to run downward - this could cause high temperatures and may present a possible fire hazard. Hampton ® H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove...
  • Page 19: Rigid Pipe Venting Systems

    , Selkirk Direct-Temp and ICC Excel. AstroCap is a proprietary trademark of ® FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent Pro are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc. Hampton ® H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove...
  • Page 20: Venting Arrangements

    The two diagrams show all allowable combinations of straight horizontal termination with one 45 elbow off the unit with Snorkels or FPI Riser Vent. Restrictor position "A". Riser Vent Termination Snorkel Termination Hampton ® H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove...
  • Page 21: Horizontal Venting With Two (2) 90 Elbows

    7' Max. between 90 elbows is 5' Max. 8' Min. 8' Max. required. Lengths do not include elbow indicated Vent restrictor position A (fully open), refer to the "Vent Restrictor Position" section. Hampton ® H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove...
  • Page 22: Vertical Venting With Two (2) 90 Elbows

    5' Max. 5' Min. between 90 elbows is required. 6' Max. 6' Min. Lengths do not include elbow indicated Vent restrictor position A (fully open), refer to the "Vent Restrictor Position" section. Hampton ® H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove...
  • Page 23: Vertical Termination With Co-Linear Flex System

    #948-305 (35 ft) Exhaust Vent Restrictors Flue set at fully open, Posiiton "A" Outer Pipe with Kit# 946-563 Air Intake Co-Linear Flex Adapter with Kit# 946-563 Inner Pipe Adapter with Kit# 946-563 Hampton ® H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove...
  • Page 24: Dv Stove Horizontal Vent Kit

    DV 2 ft. Stove Vent Kit (Part # 946-116) and DV 4 ft. Stove Vent Kit (946-216) includes all the parts needed to install the H27U-NG Direct Vent unit with minimum horizontal and vertical vent dimensions. For installations that require longer vertical and/or horizontal vents use the Dura-Vent system as shown in the "Dura-Vent Termination Kit"...
  • Page 25 3 screws terminal assembly through the wall thimbles (#8 x 1/2, stainless steel). (from the exterior into the interior) and secure the cap to the exterior wall with 4 of the supplied Hampton ® H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove...
  • Page 26: Residential And Manufactured Homes / Mobile Homes Minimum Horizontal Termination Installations

    946-205 Vinyl Siding Shield for Riser Vent Vent (76mm) Terminal #640-530/P 946-208/P Vent Guard NOTE: Ensure compliance with the outside vent terminal location before cutting hole as both dimensions must be met. Hampton ® H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove...
  • Page 27: Dura-Vent Termination Kit

    Simpson Dura-Vent® and Direct Vent Pro. The FPI AstroCap is the proprietary trademark of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent Pro are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc. Hampton ® H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove...
  • Page 28: Horizontal Terminations

    9-1/2 round hole in the exterior wall where the vent will be terminated. If the wall being penetrated is constructed of non-combustible material, i.e. masonry block or concrete, a 7" diameter hole is acceptable. Diagram 2a Diagram 3 Hampton ® H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove...
  • Page 29: Vertical Terminations

    Vent Terminal, around the bead. Ensure that the vent pipe is pushed past the bead for a secure fit. 10) Seal around the outer edge of the Riser Vent Backing Plate. Diagram 7 Hampton ® H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove...
  • Page 30: Offset Chart

    14/12 to 16/12 1.83 the shingles (shingles should overlap half the over 16/12 to 18/12 2.13 flashing) as per diagram 10. over 18/12 to 20/12 2.29 over 20/12 to 21/12 2.44 Hampton ® H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove...
  • Page 31: Converting Class-A Metal Chimney To Direct Vent System

    Diagram 5 7) The connection between the appliance and the Retro Connector may be completed with sec- tions of black direct vent pipe, together with an adjustable length. Hampton ® H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove...
  • Page 32: Cathedral Ceilings

    If the support extends above the roof, cut it flush with the top of the roof. Nail the support to the frame opening using (8) 3" spiral nails or #8 x 1-1/2" screws. Hampton ® H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove...
  • Page 33: Aeration Adjustment

    NOT covered under warranty. Note: Aeration Adjustment should only be performed by an authorized Hampton ® Installer at the time of installation or service. Hampton ® H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove...
  • Page 34: Conversion Kit #434-969 From Ng To Lp

    Lift off the Cast Top and Cast Front, remove the glass front (refer to Glass Replacement section in the H27 manual) and carefully remove the logs and lava rock (refer to Log Installation section in manual). Burner Orifice b) Remove burner by removing the 2 screws on each side and then lifting the burner tray out. Reinstall new burner orifice LPG stamped #54 and tighten. Screws Note: Use a magnetic type screwdriver if possible. 02.18.22 920-490 Hampton ® H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove...
  • Page 35 10) Check that the screw is clean and if necessary remove dirt. 11) Flip the screw (Fig. 3). Fig. 6 WARNING! Also check that the pilot and main burner injectors are appropriate Fig.3 or the gas type. Hampton ® H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove 02.18.22...
  • Page 36: Log Set Installation

    The logs are fragile, handle with care - do not force into position. The Front Right Log front edges should be placed parallel against the front edge of the burner. NOTE: This is Tabs a rear view. 918-104a Page 1 of 2 04/17/09 Hampton ® H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove...
  • Page 37 Embers Place the center cross log D so it rests in the notch located on the top of the rear log - position as shown below. Page 2 of 2 918-104a 03/17/09 Hampton ® H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove...
  • Page 38: Wall Thermostat

    Recommended Maximum Lead Length (Two-Wire) When Using Wall Thermostat (CP-2 System) Wire Size Max. Length 14 GA. 50 Ft. 16 GA. 32 Ft. 18 GA. 20 Ft. 20 GA. 12 Ft. 22 GA. 9 Ft. Hampton ® H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove...
  • Page 39: Final Check

    This appliance is equipped with a three pronged (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug. Hampton ® H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove...
  • Page 40: Operation

    Use a non-abrasive cleaner and 7) The unit should never be turned off, and on NEVER clean the glass while it is hot. again without a minimum of a 60 second wait. Lighting Procedure Hampton ® H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove...
  • Page 41: Copy Of The Lighting Plate Instructions

    DO NOT REMOVE THIS INSTRUCTION PLATE NE PAS ENLEVER CETTE ÉTIQUETTE D’INSTRUCTIONS 920-181a Part #: 920-181a Hampton ® H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove Colours: Black on Grey, except for parts indicated as being Red. Punch out .25" hole top right corner where indicated.
  • Page 42: Normal Operating Sounds Of Gas Appliances

    2) Clean glass (never when unit is hot), appliance, AND ANY GAS CONTROL WHICH and door with a damp cloth. Never use an abrasive cleaner. HAS BEEN UNDER WATER. Top View of pilot flame Hampton ® H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove...
  • Page 43: General Vent Maintenance

    3) Lift the Glass Front Assembly up. 4) a) Remove the glass and replace with the new glass. bolts Lift Rear Panel off the 2 top bolts Hampton ® H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove...
  • Page 44: Removing Valve

    3) Disconnect gas line to stove. 11) Carefully lift the burner tray assembly out. 4) Disconnect 3/8" NPT pipe from 90 elbow on valve or flex connector. 5) Disconnect the two (2) switch wires from valve. Hampton ® H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove...
  • Page 45: Gas Maintenance - Recommended Annual Routine

    • Thermocouple (millivolt models) • Air shutter setting • Thermopile (millivolt models) • Wiring Gas Leak Tests • Check main gas line connection to valve • Check shut off valve connections • Check connection at gas valve outlet • Check connection at main burner orifice • Check pilot fuel line at valve and at pilot assembly 920-324 09.14.20 Hampton ® H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove...
  • Page 46: Main Assembly

    Baffle Plate for Firebox V (Option) 144) 910-157/P Fan Motor 120 V 145) 910-233 Fan Thermodisc Auto On/Off 146) 910-794 Power Cord (120 V) 148) 910-330 Fan Speed Control (120 V) 357-007 Mesh Glass Guard Hampton ® H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove...
  • Page 47 Main Assembly Hampton ® H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove...
  • Page 48: Burner & Log Assembly

    Conversion Kit from Propane to Natural Gas 358-969 Conversion Kit from Natural Gas to Propane 358-917 Fan Kit 910-399 Remote Control 910-407 Basic Wall Thermostat 910-404/P Programmable Wall Thermostat *Note: Not available as a replacement part. Hampton ® H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove...
  • Page 49 Hampton ® H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove...
  • Page 50: Warranty

    FPI is not responsible for results or costs of workmanship of unauthorized FPI dealers or agents in the negligence of their service work. Revision Date: February 2019 Regency Gas Products Warranty Hampton ® H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove...
  • Page 51 Products made or provided by other manufacturers and used in conjunction with the FPI appliance without prior authorization from FPI may void this warranty. Revision Date: February 2019 Regency Gas Products Warranty Hampton ® H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove...
  • Page 52 To provide the best support for your product, we request that you complete a product registration form at http://www.regency-fire.com/Customer-Care/Warranty-Registration.aspx within ninety (90) days of purchase. Revision Date: February 2019 Regency Gas Products Warranty Hampton ® H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove...
  • Page 53 For fireplace care and tips and answers to most common questions please visit our Customer Care section on our Web Site. Please feel free to contact your selling dealer if you have any questions about your Regency product. Hampton ® H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove...
  • Page 54 Hampton ® H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove...
  • Page 56 Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ______________________________________________________ Serial #: ____________________________________________________________ Hampton and AstroCap™ are trademarks of FPI Fireplace Products International Ltd. ® Printed in Canada © Copyright 2022, FPI Fireplace Products International Ltd. All rights reserved.

This manual is also suitable for: