Genlock Adjust Item - JVC GY-HM790CHU Instructions Manual

Hd memory card camera recorder
Hide thumbs Also See for GY-HM790CHU:
Table of Contents

Advertisement

Menu Display and Detailed Settings
Others Menu (continued)

Genlock Adjust Item

* Default values are indicated in bold characters.
Item
Analog SD H
Phase
Analog HD H
Phase
SD-SDI H Phase
HD-SDI H Phase
Memo :
● You can alter the setting value in increments of 10 by pressing down the cross-shaped button (
(Excluding the [Analog SD H Phase] item)
96
Downloaded From VideoCamera-Manual.com Manuals
Setting Values
Min, -27 to 0 to 81, Max
For adjusting the H phase of the SD analog signal of the camera recorder with respect to
the external synchronizing signal input to the [GENLOCK INPUT] terminal.
Increase value : Advances the H phase.
Decrease value : Delays the H phase.
Min, -1023 to 0 to 1022,
For adjusting the H phase of the HD analog signal of the camera recorder with respect to
Max
the external synchronizing signal input to the [GENLOCK INPUT] terminal.
Increase value : Advances the H phase.
Decrease value : Delays the H phase.
Memo :
● When [System Definition] in the [Record Format] menu is set to ASD (DV)B, this item
appears as A---B and cannot be selected. (A Page 75)
Min, -372 to -1, 0, 1 to
For adjusting the H phase of the SD-SDI signal of the camera recorder with respect to the
372, Max
external synchronizing signal input to the [GENLOCK INPUT] terminal.
Increase value : Advances the H phase.
Decrease value : Delays the H phase.
Memo :
● When [HD/SD-SDI Out] in the [A/V Out] menu is set to a setting other than ASD (DV)B,
this item appears as A---B and cannot be selected. (A Page 92)
Min, -1023 to 0 to 1022,
For adjusting the H phase of the HD-SDI signal of the camera recorder with respect to the
Max
external synchronizing signal input to the [GENLOCK INPUT] terminal.
Increase value : Advances the H phase.
Decrease value : Delays the H phase.
Memo :
● When [HD/SD-SDI Out] in the [A/V Out] menu is set to a setting other than AHD-SDIB,
this item appears as A---B and cannot be selected. (A Page 92)
Function
JK
) for 2 seconds or longer.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gy-hm790uGy-hm790eGy-hm790che

Table of Contents