30
Event Log
The event log holds a maximum of 30 events. After the log
reaches 30 events, older events are erased to make room for
newer ones.
Each event log entry contains the following information:
The following table contains a list of events detectable by the
software.
Table 5. Event log numbers and descriptions
Event
Number
00
02
03
05
09
10
11
12
13
14
15
16
20
21
22
23
24
26
27
28
Event number
Odometer value when the event occurred
Hour meter value at the time the event occurred
Current drawn by the motor when the event occurred
(treadmill only)
Description of Event
Upper PCA memory location event
RAM location event
EEPROM checksum event
Depressed key at power up
Lower PCA memory test event
Line Frequency out of acceptable range
Watchdog (Upper PCA) low voltage power
Watchdog (Lower PCA) low voltage power
Fan at incorrect speed (version 1 treadmills)
Fan fail (Lower PCA)
AC input voltage too high
AC input voltage too low
Too many maximum power requests in one second
Too many maximum consecutive power requests
No motor pulses at start up
Motor pulses missing after start up
Reduce speed requested, speed is not reducing
Motor pulse width incorrect
Too much drive motor current
Temperature too high
Operating and Maintaining the P30 Console