2.4.2. REMOVING THE SPIT MOTOR

In order to remove the spit motor, it is sufficient to unscrew the two screws which secure it in
position (see fig. 8, pos. 5).
Fig. 8
1 - CONVECTION HEATING
ELEMENT
2. EARTH CONNECTION
3. CONNECTION FOR SPIT
MOTOR
4. SPIT MOTOR
5. SPIT MOTOR ANCHOR
SCREWS
6. CONVECTION FAN
7. CONVECTION FAN ANCHOR
SCREWS
8. CONNECTION FOR
CONVECTION FAN

2.4.3 - REMOVING THE CONVECTION FAN

Proceed as follows to remove the convection fan:
1 Remove the fan blade assembly from the inside of the oven (see fig. 10, page 8).
2 Detach the connector wires (carefully mark their position).
Remove the three screws which secure the fan in position (fig. 8, pos. 7).
2.4.4 - REMOVING THE CONVECTION FAN BLADES
Proceed as follows to remove the convection fan blades:
Remove the grilles and the drip pan from the inside of the oven.
Unscrew the four screws (fig. 9) and remove the bottom panel from inside the oven.
Fig. 9
SOI 04.04 FV
8/50
599 35 96-40