Connecting External SCSI Devices

007-4486-001
Figure 3-17
Reconnecting the Cables
The following information is covered in this section:
"Choosing a SCSI Address for the External Device"
"Setting the SCSI Address on the External Device"
"Connecting One External SCSI Device"
"Connecting More Than One External SCSI Device"
You can connect one or more external SCSI devices in a daisy-chain to the O2+
single-ended, wide SCSI bus if the maximum combined cable length of all external SCSI
cables does not exceed three meters. You can connect either 16-bit wide (68-pin) or 8-bit
narrow (50-pin) SCSI devices, but you should follow the guidelines about where to place
the devices on the chain, in "Connecting More Than One External SCSI Device."
Each device has a unique SCSI address and is connected to the other devices in a chain,
with the first device connected to the SCSI port on the rear of the workstation. The last
device on the daisy-chain must be terminated with an active SCSI terminator.