4. REPLACEMENT PROCEDURE
4.4
In the case of bizhub C353/C253/C203
4.4.1
Removal of the FK-502 (bizhub C353/C253/C203)
• In order to replace the FK-502, remove the FK-502 in the following order.
NOTE
• Be sure to check to see if the main power switch is turned off.
• The board may be damaged due to static electricity. Be sure to take an appropriate
measure against static electricity before conducting the operations.
1. Turn off the main power switch and the power switch of the main body, and then unplug
the power cord from the power outlet.
64
Field Service Ver. 9.0 Jan. 2010
2. Remove the shield box cover.
(4 screws)
3. Remove the Modular cable that is
connected.
4. Pull out the FK-502 board from the
main body. (2 hinge screws)
NOTE
• When pulling out the FK-502 board,
be sure to hold the 2 hinge screws
provided at the upper and lower
sections and pull them out to this
side.
• When reinstalling the FK-502 board,
be sure to insert it with the board
set to the groove.
• Reinstall the above parts following
the removal steps in reverse.