Signal Receiving Test - Konica Minolta FK-502 Service Manual

Network fax
Hide thumbs Also See for FK-502:
Table of Contents

Advertisement

8. TEST MODE
8.3

Signal receiving test

• Two machines are used for this test. Signal sounds can be monitored by using the moni-
tor speaker.
• Back-to-back test by connecting 2 machines directly is impossible. Use the feeding
bridge or others for this purpose.
A. Operational procedure
1. Press [Signal Receiving Test].
2. Select a test item.
3. Select the parameter you would like to test by pressing [+] or [-] key.
4. Press the [Start] key.
(In order to move to another test, select the next test item after pressing the [STOP]
key.)
Contents of Test
V17
V29
V27ter
V21
PB
Special Tone
Hi-Z Trans
*: The status of testing or results of tests are shown in the title line as follows
RCV
: Waiting signals
OK/NG : Results of signal reception
B. Detailed explanation
(1) Hi-Z Trans
• 1100Hz only (No 1300Hz)
NOTE
• The receiving test does not include the V.34 signal.
138
Parameter
14400/12000/9600/7200 [bps]
9600/7200 [bps]
4800/2400 [bps]
-
0/1/2/3/4/5/6/7/8/9/*/#/A/B/C/D
1100/1300/2100
-
Field Service Ver. 9.0 Jan. 2010
15LAF3E043DA
Factory-shipped
default setting
14400 [bps]
9600 [bps]
4800 [bps]
-
0
1100
-