Konica Minolta FK-502 Service Manual page 160

Network fax
Hide thumbs Also See for FK-502:
Table of Contents

Advertisement

Field Service Ver. 9.0 Jan. 2010
4. Press the [Start] key.
(In order to move to another test, select the next test item after pressing the [Stop] key.)
Contents of Test
V34 Main CH
V34 Control CH
V8
V17
V29
V27ter
V21
PB
DP
Special Tone
Optional Tone
PB Tone (High)
PB Tone (Low)
Pseudo Ring
B. Detailed explanation
(1) Signal Sending Test
• Signal is output from pressing [Start] to pressing [Stop].
Parameter
33600 / 31200 / 28800 / 26400 /
24000 / 21600 / 19200 / 16800 /
14400 / 12000 / 9600 / 7200 /
4800 / 2400 [bps]
CTL CH / INFOc / INFOa /
ToneB / ToneA
CM / JM
14400 / 12000 / 9600 /
7200 [bps]
9600 / 7200 [bps]
4800 / 2400 [bps]
-
0 / 1 / 2 / 3 / 4 / 5 / 6 / 7 / 8 / 9 /
* / # / A / B / C / D
0 / 1 / 2 / 3 / 4 / 5 / 6 / 7 / 8 / 9
1100 / 1300 / 1650 / 2100
200 to 4000 [Hz] (In steps of 100Hz)
1209 / 1336 / 1477 / 1633 [Hz]
697 / 770 / 852 / 941 [Hz]
-
8. TEST MODE
Factory-shipped
default setting
33600 [bps]
CTL CH
CM
14400 [bps]
9600 [bps]
4800 [bps]
-
0
0
1100 [Hz]
200 [Hz]
1209 [Hz]
697 [Hz]
-
137