Ports - ADC SUPER SIX S-100 Technical Manual

Single board computer
Hide thumbs Also See for SUPER SIX S-100:
Table of Contents

Advertisement

3.2.21
Port 18
This write-only port acts as the set-baud-rate port and allows the user to perform a
software reset of the baud rate for SIO channels
A
and
B.
The bit significance of this port
is shown below.
D7
=
MSB; DO
=
LSB
510
channel
A
baud bit
A
--~
SIO channel A baud bit B
' - - - - - -
510
channel A baud bit
C
' - - - - - - - - - . 5 1 0 channel-A baud bit
D
.....- - - - - - - - -.. 510 channel B baud bit
A
.....- - - - - - - - - - -
510 channel B baud bit
B
.....- - - - - - - - - - - - -
510 channel B baud bit
C
110------------------1
510 channel B baud bit
D
The baud rates equated with bit settings A, B, C, and D are shown in Table 3-2. These are
identical for both channel A and channel
B.
BIT
BIT
BIT
BIT
BAUD
D
C
B
A
RATE
0
0
0
0
50
0
0
0
1
75
0
0
I
0
110
0
0
I
I
134.5
0
1
0
0
150
0
1
0
I
300
0
I
1
0
600
0
1
I
1
1200
1
0
0
0
1800
1
0
0
1
2000
1
0
1
0
2400
1
0
1
I
3600
I
1
0
0
4800
1
1
0
1
7200
1
1
1
0
9600
1
1
1
1
19,200
Table 3-2. SUPER SIX Port 18 Baud Rate Settings
-21-

Advertisement

Table of Contents
loading

Table of Contents