Eaton Powerware 5125 Installation Manual

Installation guide for ibm applications
Hide thumbs Also See for Powerware 5125:

Advertisement

Powerware 5125 (9910-E33) UPS
®
®
Installation Guide for IBM Applications

Advertisement

Table of Contents
loading

Summary of Contents for Eaton Powerware 5125

  • Page 1 Powerware 5125 (9910-E33) UPS ® ® Installation Guide for IBM Applications...
  • Page 2 Linux is a registered trademark of Linus Torvalds. Burndy is a registered trademark of Framatone Connectors International. ECopyright 2007 Eaton Corporation, Raleigh, NC, USA. All rights reserved. No part of this document may be reproduced in any way without the express written approval of Eaton Corporation.
  • Page 3: Table Of Contents

    ..........® ® EATON Powerware 5125 (9910-E33) UPS Installation Guide for IBM Applications...
  • Page 4 TABLE OF CONTENTS This page intentionally left blank. ® ® EATON Powerware 5125 (9910-E33) UPS Installation Guide for IBM Applications 164201695 Rev 1...
  • Page 5: Installation

    * If the UPS is factory-installed in an IBM rack, these items are pre-assembled. Table 2. E33 Application Matrix Quantity for Quantity for IBM MN IBM FC IBM PN Eaton PN Description p5/pSeries i5/iSeriest ® Rack Worldwide Rack Worldwide —...
  • Page 6 INSTALLATION Table 3. E33 Accessory Kit (42R8066) Quantity Eaton PN Description 164201383 Powerware 5125 Two-in-One UPS (2400/3000 VA) User’s Guide 164201695 Powerware 5125 (9910-E33) Installation Guide for IBM Applications 164201568 Read Me First Card 152601942-001 IEC 320-C13 to C14, 10A Equipment Power Cords (2m/6.6 ft) 152601971-001 IEC 320-C19 to C20, 16A Equipment Power Cord (4.5m/14.8 ft)
  • Page 7: Ups Internal Battery Connection

    INSTALLATION Table 5. EBM Accessory Kit (42R8068) Quantity Eaton PN Description 164201378 Powerware 5125 Two-in-One EBM (2500/3000 VA) User’s Guide 152602008 EBM Cable 103002843-3992 Rail Hardware Kit (metric): × S (8) M5 12 Pan-Head Screws × S (8) M5 10 Flat-Head Screws ×...
  • Page 8: Setup And Installation

    Installation” on page 10 or “UPS Installation” on page 11. Tools Required To assemble the components, the following tools may be needed: Medium flat-bladed screwdriver #2 Phillips screwdriver 8 mm wrench or socket ® ® EATON Powerware 5125 (9910-E33) UPS Installation Guide for IBM Applications 164201695 Rev 1...
  • Page 9: Rack-Mount Setup

    (see Figure 4). Rear Hold-Down Bracket Front Rear Assembly Wing Nuts Figure 4. Adjusting the Rail Depth ® ® EATON Powerware 5125 (9910-E33) UPS Installation Guide for IBM Applications 164201695 Rev 1...
  • Page 10 The bottom rail uses positions 2 and 4 for the rear hex-head screws. If you are installing additional rails, place the next rail 4 holes above the last installed screw. ® ® EATON Powerware 5125 (9910-E33) UPS Installation Guide for IBM Applications 164201695 Rev 1...
  • Page 11 Figure 7. Securing the Rear of the Rail Repeat Steps 3 and 4 for the other rail. Tighten the assembly wing nuts on all rail assemblies. ® ® EATON Powerware 5125 (9910-E33) UPS Installation Guide for IBM Applications 164201695 Rev 1...
  • Page 12 NOTE The EBMs must be installed below the UPS as shown in Figure 9. Optional EBMs Figure 9. Rack-Mount UPS with EBMs ® ® EATON Powerware 5125 (9910-E33) UPS Installation Guide for IBM Applications 164201695 Rev 1...
  • Page 13 13. Tighten the pan-head screws that secure both rails to the front of the rack (see Step 3 on page 6). 14. Continue to the following section, “EBM Installation,” or “UPS Installation” on page 11. ® ® EATON Powerware 5125 (9910-E33) UPS Installation Guide for IBM Applications 164201695 Rev 1...
  • Page 14: Ebm Installation

    Input Connector Power Cord Circuit Breakers UPS Battery Connector Output Receptacles REPO Port EBM Battery Cable Connectors Battery Circuit Breaker Figure 12. Typical EBM Installation ® ® EATON Powerware 5125 (9910-E33) UPS Installation Guide for IBM Applications 164201695 Rev 1...
  • Page 15: Ups Installation

    “Remote Emergency Power-off Installation,” to install the REPO switch before powering on the UPS. Continue to “Power Connections and Startup” on page 14. ® ® EATON Powerware 5125 (9910-E33) UPS Installation Guide for IBM Applications 164201695 Rev 1...
  • Page 16: Remote Emergency Power-Off Installation

    To install the REPO switch: Verify that the UPS is off and unplugged. Remove the REPO connector from the REPO port on the UPS rear panel. ® ® EATON Powerware 5125 (9910-E33) UPS Installation Guide for IBM Applications 164201695 Rev 1...
  • Page 17 Plug in the UPS and start the UPS by pressing the On button. Activate the external REPO switch to test the REPO function. De-activate the external REPO switch and restart the UPS. ® ® EATON Powerware 5125 (9910-E33) UPS Installation Guide for IBM Applications 164201695 Rev 1...
  • Page 18: Power Connections And Startup

    UPS output receptacle (see Figure 16) using the supplied power cord. Then plug the second (redundant) PDU power cord into a non-UPS protected output receptacle (mains) or into a second UPS. ® ® EATON Powerware 5125 (9910-E33) UPS Installation Guide for IBM Applications 164201695 Rev 1...
  • Page 19 If you installed an optional EBM(s), remove the breaker tie from all battery circuit breakers. Switch all battery circuit breakers to the ON ( ) position. ® ® EATON Powerware 5125 (9910-E33) UPS Installation Guide for IBM Applications 164201695 Rev 1...
  • Page 20 UPS is in Standby mode with the equipment offline. If the alarm beeps or a UPS alarm indicator stays on, refer to “Troubleshooting” in the Powerware 5125 Two-in-One UPS (2400/3000 VA) User’s Guide. Press and hold the On button until you hear the UPS beep (approximately one second).
  • Page 21 Burndy to KP, 4.3m/14 ft * Other power cords are supported by the PDU. Power cords shown are similar in voltage and amperage to the UPS. ® ® EATON Powerware 5125 (9910-E33) UPS Installation Guide for IBM Applications 164201695 Rev 1...
  • Page 22 NOTE E33 does not supp NOTE E33 has a maximum output capacity of 2700 watts even though IBM PDU 7188 or 9188 can support higher power output. Plan accordingly. ® ® EATON Powerware 5125 (9910-E33) UPS Installation Guide for IBM Applications 164201695 Rev 1...
  • Page 23 INSTALLATION Mains Varies Eaton (6) Varies (5) iSeries 2700W pSeries 5889, 7109, 7188, or 9188 Figure 18. E33 with Non-Redundant Power Mains Varies Eaton (6) Varies (5) iSeries 2700W pSeries 5889, 7109, 7188, or 9188 Mains Varies IBM (7) iSeries...
  • Page 24: Load Segments

    The E33 has three load segments as shown in Figure 20. Load Segment 2 Load Segment 1 Load Segment 3 Figure 20. UPS Load Segments ® ® EATON Powerware 5125 (9910-E33) UPS Installation Guide for IBM Applications 164201695 Rev 1...
  • Page 25: Operation

    UPS transfers to Standby mode (if utility power is available) and removes power from your equipment. Unplug the UPS. If you do not unplug the UPS, it remains in Standby mode. ® ® EATON Powerware 5125 (9910-E33) UPS Installation Guide for IBM Applications 164201695 Rev 1...
  • Page 26: Operating Modes

    OPERATION Operating Modes The Powerware 5125’s front panel indicates the UPS status through the UPS indicators. Figure 21 shows the UPS front panel indicators and controls. Indicator Legend Unlit Normal Mode Indicator (Solid Green) Green Standby Mode Indicator (Flashing Green)
  • Page 27: Battery Mode

    NOTE For 200–240V models, the output receptacles may remain electrically live (up to 100–120V). Unplug the UPS to ensure power is not available to the output receptacles. ® ® EATON Powerware 5125 (9910-E33) UPS Installation Guide for IBM Applications 164201695 Rev 1...
  • Page 28: Configuration Mode

    Press the button to confirm the selection and exit Configuration mode. If you do not press the button, the UPS defaults to the original settings. ® ® EATON Powerware 5125 (9910-E33) UPS Installation Guide for IBM Applications 164201695 Rev 1...
  • Page 29 Press the Off button ONCE to Press the Alarm Reset button select the option. to save the setting and exit Configuration mode. Figure 23. Using Configuration Mode ® ® EATON Powerware 5125 (9910-E33) UPS Installation Guide for IBM Applications 164201695 Rev 1...
  • Page 30 Alarm DOES NOT sound when the polarity of the outlet is reversed or the ground connection is missing. * Site Wiring Fault is not available for 100, 200, or 208V models. ® ® EATON Powerware 5125 (9910-E33) UPS Installation Guide for IBM Applications 164201695 Rev 1...
  • Page 31: Communication

    The cable pins are identified in Figure 24 and the pin functions are described in Table 9. Figure 24. Communication Port ® ® EATON Powerware 5125 (9910-E33) UPS Installation Guide for IBM Applications 164201695 Rev 1...
  • Page 32 Figure 25. Removing the Single-Port Card Move the J3 jumper to the AS/400 position to enable the ® On-Bypass relay as shown in Figure 26. ® ® EATON Powerware 5125 (9910-E33) UPS Installation Guide for IBM Applications 164201695 Rev 1...
  • Page 33 Align the Single-Port Card with the slot guides and slide the card into the slot until it is firmly seated. Secure the Single-Port Card with the screws removed in Step 1. ® ® EATON Powerware 5125 (9910-E33) UPS Installation Guide for IBM Applications 164201695 Rev 1...
  • Page 34: Communication Options

    To connect the UPS to an i5, iSeries, or AS/400 and a serial server you need: An Eaton-supplied Relay-Serial Card, an AS/400 interface cable (labeled 152601976-001), and a serial interface cable (labeled 124102044-001), located in the FC 2939 carton labeled “Cable Kit for IBM iSeries and Windows or AIX/Linux Servers”...
  • Page 35 UPS Interface Cable (labeled 1827) Serial Interface Cable AS/400 Interface Cable (labeled 152601976-001) (labeled 124102044-003) Relay-Serial Card Communication Port Figure 27. i5 and Serial Server Interface ® ® EATON Powerware 5125 (9910-E33) UPS Installation Guide for IBM Applications 164201695 Rev 1...
  • Page 36 Serial (TTY) Server Serial Interface Cable (labeled 124102044-003) AS/400 Interface Cable (labeled 152601976-001) Relay-Serial Card Communication Port Figure 28. iSeries or AS/400 and Serial Server Interface ® ® EATON Powerware 5125 (9910-E33) UPS Installation Guide for IBM Applications 164201695 Rev 1...
  • Page 37: Serial (Tty) Interface Overview

    Serial (TTY) Interface Overview To serially (TTY) connect the UPS to a p5, pSeries, RS/6000, OpenPower or other system you need: An Eaton-supplied serial interface cable (labeled 124102043-001), located in the E33 accessory kit Powerware LanSafe Power Management Software from the...
  • Page 38: P5 Or Pseries With Logical Partitions Interface Overview

    Logical Partitions Interface Overview To connect the UPS to a p5 or pSeries with LPARs you need: An Eaton-supplied ConnectUPS-X Web/SNMP Card, located in the FC 2934 carton labeled “ConnectUPS-X Web/SNMP Card Kit” NetWatch software from the Software Suite CD, located in the E33...
  • Page 39: Service And Support

    Figure 31. Example of IBM Serial Number Labels Comments We welcome your comments about this manual. Please send your questions or suggestions for improvements to ibm.ups@powerware.com. ® ® EATON Powerware 5125 (9910-E33) UPS Installation Guide for IBM Applications 164201695 Rev 1...
  • Page 40 SERVICE AND SUPPORT This page intentionally left blank. ® ® EATON Powerware 5125 (9910-E33) UPS Installation Guide for IBM Applications 164201695 Rev 1...
  • Page 41 92/31/EEC, Amending Directive 89/336/EEC relating to EMC The EC Declaration of Conformity is available upon request for products with a CE mark. For copies of the EC Declaration of Conformity, contact: Eaton Power Quality Oy Koskelontie 13 FIN-02920 Espoo Finland...
  • Page 42 This page intentionally left blank.
  • Page 44 *1642016951* 164201695 1...

This manual is also suitable for:

Powerware 5125 9910-e33

Table of Contents