Page 1
Powerware Series ® Eaton 5115 Tower UPS 500–1400 VA User's Guide...
Page 2
National Electrical Code and NEC are registered trademarks of National Fire Protection Association, Inc. All other trademarks are property of their respective companies. ECopyright 2000–2010 Eaton Corporation, Raleigh, NC, USA. All rights reserved. No part of this document may be reproduced in any way without the express written approval of Eaton Corporation.
Page 3
89/336/EEC, Council Directive relating to electromagnetic compatibility 92/31/EEC, Amending Directive 89/336/EEC relating to EMC The EC Declaration of Conformity is available upon request for products with a CE mark. For copies of the EC Declaration of Conformity, contact: Eaton Corporation Koskelontie 13 FIN-02920 Espoo Finland...
Special Symbols The following are examples of symbols used on the UPS to alert you to important information: CAUTION Risk of Electric Shock Do Not Open Cover CAUTION To reduce the risk of electric shock, Do not remove cover (or back) No user-serviceable parts inside Refer servicing to the factory RISK OF ELECTRIC SHOCK...
— causing hours of lost productivity and expensive repairs. With the Eaton 5115, you can safely eliminate the effects of power disturbances and guard the integrity of your equipment. The Eaton...
Page 8
INTRODUCTION Providing outstanding performance and reliability, the Eaton 5115's unique benefits include: Buck and Boost voltage regulation that ensures consistent voltage to your load by correcting voltage fluctuations. technology that uses advanced battery management to ® increase battery service life, optimize recharge time, and provide a warning before the end of useful battery life.
UPS must not have an earth leakage current greater than 1.5 milliamperes. If the UPS requires any type of transportation, disconnect the internal UPS batteries before transporting (see page 39). 05146640 Rev D www.eaton.com/powerquality Eaton 5115 Tower UPS (500–1400 VA) User's Guide...
Page 10
UPS-ledningsføringen). Netledningen må ikke fjernes og stikket må ikke trækkes ud, mens UPS'en er tændt. Dette fjerner sikkerhedsjorden fra UPS'en og fra det udstyr, der er sat til. 05146640 Rev D www.eaton.com/powerquality Eaton 5115 Tower UPS (500–1400 VA) User's Guide...
Deze UPS bevat LEVENSGEVAARLIJKE ELEKTRISCHE SPANNING. Alle reparaties en onderhoud dienen UITSLUITEND DOOR ERKEND SERVICEPERSONEEL te worden uitgevoerd. Er bevinden zich GEEN ONDERDELEN in de UPS die DOOR DE GEBRUIKER kunnen worden GEREPAREERD. 05146640 Rev D www.eaton.com/powerquality Eaton 5115 Tower UPS (500–1400 VA) User's Guide...
Page 12
Vervang de accu's door accu's met hetzelfde nummer en van hetzelfde type als de oorspronkelijke accu's in de UPS. 05146640 Rev D www.eaton.com/powerquality Eaton 5115 Tower UPS (500–1400 VA) User's Guide...
Page 13
2) Käytä työkaluja, joissa on eristetyt kädensijat. 3) Älä aseta työkaluja tai metalliosia akkujen päälle. 4) Irrota latauslähde ennen akun napojen kytkemistä tai irrotusta. Akusto täytyy hävittää säädösten mukaisella tavalla. Noudata paikallisia määräyksiä. 05146640 Rev D www.eaton.com/powerquality Eaton 5115 Tower UPS (500–1400 VA) User's Guide...
Page 14
La température ambiante ne doit pas dépasser 40 °C. Ne pas utiliser à proximité d'eau ou dans une atmosphère excessivement humide (95 % maximum). 05146640 Rev D www.eaton.com/powerquality Eaton 5115 Tower UPS (500–1400 VA) User's Guide...
W A R N U N G Die USV führt lebensgefährliche Spannungen. Alle Reparatur- und Wartungsarbeiten sollten nur von Kundendienstfachleuten durchgeführt werden. Die USV enthält keine vom Benutzer zu wartenden Komponenten. 05146640 Rev D www.eaton.com/powerquality Eaton 5115 Tower UPS (500–1400 VA) User's Guide...
Page 16
Die Batterie(n) nicht öffnen oder baulich verändern. Ausfließendes Elektrolyt ist schädlich für Haut und Augen. Falls Sie die Batterien austauschen, verwenden Sie bitte ausschließlich die gleiche Anzahl und die Batterietypen. 05146640 Rev D www.eaton.com/powerquality Eaton 5115 Tower UPS (500–1400 VA) User's Guide...
Per conformità con gli standard internazionali e con le norme in merito al cablaggio, tutta l'apparecchiatura collegata con l'uscita del gruppo statico di continuità non deve avere una corrente di dispersione di terra superiore a 1,5 milliampere. 05146640 Rev D www.eaton.com/powerquality Eaton 5115 Tower UPS (500–1400 VA) User's Guide...
0 V dersom din enhets strømkilde er fase-til-nøytral (som på de fleste europeiske enheter). Med ledningsført fase-til-fase inngang vil spenningen til utgangsstikkene være 110–120V (målt fra fase-til-jord eller fase-til-nøytral, avhenging av UPS-ledningsføringen). 05146640 Rev D www.eaton.com/powerquality Eaton 5115 Tower UPS (500–1400 VA) User's Guide...
Page 19
A UPS contém VOLTAGEM MORTAL. Todos os reparos e assistência técnica devem ser executados SOMENTE POR PESSOAL DA ASSISTÊNCIA TÉCNICA AUTORIZADO. Não há nenhuma PEÇA QUE POSSA SER REPARADA PELO USUÁRIO dentro da UPS. 05146640 Rev D www.eaton.com/powerquality Eaton 5115 Tower UPS (500–1400 VA) User's Guide...
Page 20
Não abra nem danifique a(s) bateria(s). O eletrólito liberado é prejudicial à pele e aos olhos e pode ser extremamente tóxico. Ao realizar a troca das baterias, utilize a mesma quantidade e o mesmo tipo de bateria instalada originalmente no no-break. 05146640 Rev D www.eaton.com/powerquality Eaton 5115 Tower UPS (500–1400 VA) User's Guide...
Este SAI contiene VOLTAJES MORTALES. Todas las reparaciones y el servicio técnico deben ser efectuados SOLAMENTE POR PERSONAL DE SERVICIO TÉCNICO AUTORIZADO. No hay NINGUNA PARTE QUE EL USUARIO PUEDA REPARAR dentro del SAI. 05146640 Rev D www.eaton.com/powerquality Eaton 5115 Tower UPS (500–1400 VA) User's Guide...
Page 23
No abra ni corte las baterías. El electrolito liberado es peligroso para la piel y los ojos, y puede ser extremadamente tóxico. Reemplace las baterías con el mismo número y tipo de baterías como se instalaron originalmente en el SAI. 05146640 Rev D www.eaton.com/powerquality Eaton 5115 Tower UPS (500–1400 VA) User's Guide...
Page 24
Följande försiktighetsåtgärder skall iakttagas: 1) Ta av klockor, ringar och andra metallobjekt. 2) Använd verktyg med isolerade grepp. 3) Lägg inte verktyg eller metalldelar ovanpå batterierna. 4) Koppla bort laddningskällan före anslutning eller bortkoppling av batteripolerna. 05146640 Rev D www.eaton.com/powerquality Eaton 5115 Tower UPS (500–1400 VA) User's Guide...
Page 25
Öppna eller förstör inte batteriet eller batterierna. Utsläppt elektrolyt är skadlig för hud och ögon och kan vara mycket giftig. Byt ut batterierna mot samma antal och typer av batterier som ursprungligen installerats i UPS-enheten. 05146640 Rev D www.eaton.com/powerquality Eaton 5115 Tower UPS (500–1400 VA) User's Guide...
NOTE Check the battery recharge date on the shipping carton label. If the date has expired and the batteries were never recharged, do not use the UPS. Contact your service representative. 05146640 Rev D www.eaton.com/powerquality Eaton 5115 Tower UPS (500–1400 VA) User's Guide...
Figure 2. Removing the UPS Front Cover Slide up and remove the metal battery cover (see Figure 3). 500–1000 VA 1400 VA Figure 3. Removing the Battery Cover 05146640 Rev D www.eaton.com/powerquality Eaton 5115 Tower UPS (500–1400 VA) User's Guide...
Page 29
Connect the red wire to the ()) battery connector (see Figure 5). Figure 5. Connecting the Internal Battery Connector Replace the metal battery cover. Replace the UPS front cover. 05146640 Rev D www.eaton.com/powerquality Eaton 5115 Tower UPS (500–1400 VA) User's Guide...
UPS (optional) Verify DIP switch Press the button (on the front panel) & Connect UPS to power Connect equipment to UPS Figure 6. Typical UPS Installation (120V Model Shown) 05146640 Rev D www.eaton.com/powerquality Eaton 5115 Tower UPS (500–1400 VA) User's Guide...
Page 31
NOTE The batteries charge to 90% capacity in approximately 3 hours. However, it is recommended that the batteries charge for 6 to 24 hours after installation or long-term storage. 05146640 Rev D www.eaton.com/powerquality Eaton 5115 Tower UPS (500–1400 VA) User's Guide...
INSTALLATION UPS Rear Panels This section shows the rear panels of the Eaton 5115 models. DIP Switches USB Port Site Wiring Fault Indicator Network Transient Protector Communication Port Four 5‐15 Receptacles Input Overcurrent Protector 6-ft Power Cord with 5‐15 Plug Figure 7.
Page 33
Communication Port Site Wiring Fault Indicator Network Transient Protector Six 5‐15 Receptacles Input Overcurrent Protector 6-ft Power Cord with 5‐15 Plug Figure 10. 1400 VA, 120V Rear Panel 05146640 Rev D www.eaton.com/powerquality Eaton 5115 Tower UPS (500–1400 VA) User's Guide...
Page 34
Figure 11. 500 VA, 230V Rear Panel DIP Switches USB Port Communication Port Network Transient Protector Four 10A, IEC-320 Receptacles 10A, IEC-320 Input Connector Figure 12. 750 VA, 230V Rear Panel 05146640 Rev D www.eaton.com/powerquality Eaton 5115 Tower UPS (500–1400 VA) User's Guide...
Page 35
Figure 13. 1000 VA, 230V Rear Panel DIP Switches USB Port Communication Port Network Transient Protector Six 10A, IEC-320 Receptacles 10A, IEC-320 Input Connector Figure 14. 1400 VA, 230V Rear Panel 05146640 Rev D www.eaton.com/powerquality Eaton 5115 Tower UPS (500–1400 VA) User's Guide...
The UPS starts up in Battery mode and supplies battery power to your equipment. When the UPS starts on battery, it does not conduct a self‐test to conserve battery power. 05146640 Rev D www.eaton.com/powerquality Eaton 5115 Tower UPS (500–1400 VA) User's Guide...
The battery recharges when necessary. NOTE For 220–240V models, the output receptacles may remain electrically live (up to 110–120V). Unplug the UPS to ensure power is not available to the output receptacles. 05146640 Rev D www.eaton.com/powerquality Eaton 5115 Tower UPS (500–1400 VA) User's Guide...
During the five-second test, the bar graph indicators cycle through twice. If the alarm beeps or a UPS alarm indicator stays on, see “Troubleshooting” on page 51. 05146640 Rev D www.eaton.com/powerquality Eaton 5115 Tower UPS (500–1400 VA) User's Guide...
Plug the UPS power cord into a power outlet. Press and hold the button until you hear the UPS beep (approximately two seconds) to turn the UPS on. UPS Rear Panel Figure 16. DIP Switches 05146640 Rev D www.eaton.com/powerquality Eaton 5115 Tower UPS (500–1400 VA) User's Guide...
Connect the other end of the USB cable to the USB port on your computer. USB Port Figure 17. The USB Port Install the LanSafe software and USB drivers according to the instructions provided with the Software Suite CD. 05146640 Rev D www.eaton.com/powerquality Eaton 5115 Tower UPS (500–1400 VA) User's Guide...
To external device (tied to Pin 4) — No Connection — AC Fail AC Fail relay contact; 20 mA, 30 Vdc contact rating Power Source +V (8 to 24 volts DC power) 05146640 Rev D www.eaton.com/powerquality Eaton 5115 Tower UPS (500–1400 VA) User's Guide...
Connect the input connector of the equipment you are protecting to the jack labeled IN. Connect the network or telephone (low voltage models only) cable to the jack labeled OUT. Figure 19. Network Transient Protector 05146640 Rev D www.eaton.com/powerquality Eaton 5115 Tower UPS (500–1400 VA) User's Guide...
Verify that the UPS is unplugged and turned off. Disconnect the UPS internal battery connector using the steps in “Connecting the UPS Internal Battery” on page 22 in reverse order. 05146640 Rev D www.eaton.com/powerquality Eaton 5115 Tower UPS (500–1400 VA) User's Guide...
C A U T I O N Pull the battery out onto a flat, stable surface. The battery is unsupported when you pull it out of the UPS. 05146640 Rev D www.eaton.com/powerquality Eaton 5115 Tower UPS (500–1400 VA) User's Guide...
Page 47
Figure 20. Removing the UPS Front Cover Slide up and remove the metal battery cover (see Figure 21). 500–1000 VA 1400 VA Figure 21. Removing the Battery Cover 05146640 Rev D www.eaton.com/powerquality Eaton 5115 Tower UPS (500–1400 VA) User's Guide...
Page 48
Disconnect the black battery cable. Pull the battery out onto a flat, stable surface. Continue to Step 14 on page 44. Figure 22. Removing the Battery (500 VA Models) 05146640 Rev D www.eaton.com/powerquality Eaton 5115 Tower UPS (500–1400 VA) User's Guide...
Page 49
Pull the battery out onto a flat, stable surface. Disconnect the black battery cable to the UPS. 10. Continue to Step 14. Figure 23. Removing the Battery (750/1000 VA Models) 05146640 Rev D www.eaton.com/powerquality Eaton 5115 Tower UPS (500–1400 VA) User's Guide...
Page 50
NOTE A small amount of arcing may occur when connecting the batteries. This is normal and does not damage the unit or present any safety concern. 19. Replace the metal battery cover and UPS front cover. 05146640 Rev D www.eaton.com/powerquality Eaton 5115 Tower UPS (500–1400 VA) User's Guide...
C A U T I O N Do not discard waste electrical or electronic equipment (WEEE) in the trash. For proper disposal, contact your local recycling/reuse or hazardous waste center. 05146640 Rev D www.eaton.com/powerquality Eaton 5115 Tower UPS (500–1400 VA) User's Guide...
Page 55
Advanced charging for faster recovery; approximately 3 hours to 90% usable capacity at nominal line and no supplementary power supply load Monitoring Advanced monitoring for earlier failure detection and warning 05146640 Rev D www.eaton.com/powerquality Eaton 5115 Tower UPS (500–1400 VA) User's Guide...
Page 56
UPS Models by VA Ratings Load (VA) Watts 1000 1400 1000 1200 1400 NOTE Battery times are approximate and may vary depending on the load configuration and battery charge. 05146640 Rev D www.eaton.com/powerquality Eaton 5115 Tower UPS (500–1400 VA) User's Guide...
The alarm does not silence if there is a UPS fault, low battery condition, or if the battery needs to be replaced. 05146640 Rev D www.eaton.com/powerquality Eaton 5115 Tower UPS (500–1400 VA) User's Guide...
1 beep every 2 seconds. The battery is running low. (depending on load configuration and battery charge). Save your work and turn off your equipment. The alarm cannot be silenced. 05146640 Rev D www.eaton.com/powerquality Eaton 5115 Tower UPS (500–1400 VA) User's Guide...
Page 59
Continuous beep. UPS fan fault (750–1400 VA Save your work and turn off your equipment. Turn off models only). the UPS. Contact your service representative. 05146640 Rev D www.eaton.com/powerquality Eaton 5115 Tower UPS (500–1400 VA) User's Guide...
Page 60
The output voltage is Save your work and turn off your equipment. Turn off below or above the limit the UPS. Contact your service representative. while the UPS is on battery. 05146640 Rev D www.eaton.com/powerquality Eaton 5115 Tower UPS (500–1400 VA) User's Guide...
A replacement or repair unit will be shipped, freight prepaid for all warrantied units. Help NOTE For critical applications, immediate replacement may be available. Call the Desk for the dealer or distributor nearest you. 05146640 Rev D www.eaton.com/powerquality Eaton 5115 Tower UPS (500–1400 VA) User's Guide...
This limited warranty (this “Warranty”) applies only to the original End-User (the “End-User”) of any Eaton 3105, 5110, 5115, 5125, and 5130 Products (individually and collectively, the “Product”) purchased on or after August 19, 2009 and cannot be transferred. This Warranty applies even in the event that the Product is initially sold by Company for resale to an End-User.
Page 64
Product is sold, Company shall have no obligation under this Warranty. Also during such time, the period of this Warranty shall continue to run and the expiration of this Warranty shall not be extended upon payment of any overdue or unpaid amounts. 05146640 Rev D www.eaton.com/powerquality Eaton 5115 Tower UPS (500–1400 VA) User's Guide...
In the USA, call the Customer Reliability Center 7x24 at 800-356-5737. Outside of the USA, call your local Eaton product sales or service representative. For comments or questions about this Warranty, write to the Customer Quality Representative, 3301 Spring Forest Road, Raleigh, North Carolina 27616 USA.
Page 66
This Guaranty is not valid: (a) unless the End-User returns to Company the Warranty Registration Card or completes the registration form on www.eaton.com/PQ/Register within thirty (30) days of purchase; or (b) if the Product's serial numbers have been removed or are illegible.