  • Page 1 Powerware 5125 (9910-E65) UPS ® ® Installation Guide for IBM Applications...
  • Page 2 Linux is a registered trademark of Linus Torvalds. Burndy is a registered trademark of Framatone Connectors International. ECopyright 2007 Eaton Corporation, Raleigh, NC, USA. All rights reserved. No part of this document may be reproduced in any way without the express written approval of Eaton Corporation.
  • Page 3: Special Symbols

    Special Symbols The following are examples of symbols used on the UPS or accessories to alert you to important information: RISK OF ELECTRIC SHOCK - Indicates that a risk of electric shock is present and the associated warning should be observed. CAUTION: REFER TO OPERATOR’S MANUAL - Refer to your operator’s manual for additional information, such as important operating and maintenance instructions.
  • Page 4 This page intentionally left blank.
  • Page 5: Table Of Contents

    ..........® ® EATON Powerware 5125 (9910-E65) UPS Installation Guide for IBM Applications...
  • Page 6 TABLE OF CONTENTS This page intentionally left blank. ® ® EATON Powerware 5125 (9910-E65) UPS Installation Guide for IBM Applications 164201698 Rev 1...
  • Page 7: Installation

    * If the UPS is factory-installed in an IBM rack, these items are pre-assembled. Table 2. E65 Application Matrix Quantity for Quantity for IBM MN IBM FC IBM PN Eaton PN Description p5/pSeries i5/iSeries ® Rack Worldwide Rack Worldwide —...
  • Page 8 Table 4. E65 Accessory Kit (42R8078) Quantity Eaton PN Description 164201541 Powerware 5125 Rack-Mount UPS (5000/6000 VA) User’s Guide 164201698 Powerware 5125 (9910-E65) Installation Guide for IBM Applications 152601942-001 IEC 320-C13 to C14, 10A Equipment Power Cords (2m/6.6 ft) 152601971-001 IEC 320-C19 to C20, 16A Equipment Power Cord (4.5m/14.8 ft)
  • Page 9: Setup And Installation

    INSTALLATION Table 5. E65 6645 EBM Components (42R8075) Quantity IBM MN IBM FC IBM PN Eaton PN Description — 6645 42R8075 103003387-3992 E65 6645 EBM 3U High (in shipping carton or factory-installed in rack)* 103006308 Accessory Kit*: S (1) EBM Front Cover (157604790-002)
  • Page 10: Tools Required

    Left adjustable rail assembly (located in the UPS and EBM cartons) Right adjustable rail assembly (located in the UPS and EBM cartons) Rail hardware kit (located in the E65 UPS and EBM accessory kits) ® ® EATON Powerware 5125 (9910-E65) UPS Installation Guide for IBM Applications 164201698 Rev 1...
  • Page 11 Place the first rail at the bottom, using positions 1 and 6 for the front pan-head screws. If you are installing additional rails, place the next rail 4 holes above the last installed screw (see Figure 2). ® ® EATON Powerware 5125 (9910-E65) UPS Installation Guide for IBM Applications 164201698 Rev 1...
  • Page 12 Insert the screws through positions 3 and 4 of the rail (see Figure 3). NOTE Do not tighten the screws until the UPS or EBM is installed. ® ® EATON Powerware 5125 (9910-E65) UPS Installation Guide for IBM Applications 164201698 Rev 1...
  • Page 13 7 holes above the last installed screw. Position 13 Second Rail Position 11 Position 4 First Rail Position 2 Figure 4. Rear Rack Screw Positions ® ® EATON Powerware 5125 (9910-E65) UPS Installation Guide for IBM Applications 164201698 Rev 1...
  • Page 14 Figure 5. Securing the Rear of the Rail Repeat Steps 3 and 4 for each rail. Tighten the assembly wing nuts on all rail assemblies. ® ® EATON Powerware 5125 (9910-E65) UPS Installation Guide for IBM Applications 164201698 Rev 1...
  • Page 15 3/8” flat-head screws (see Figure 6). If installing an optional EBM, repeat Steps 7 and 8 for each cabinet. Mounting Bracket Figure 6. Installing the Mounting Brackets ® ® EATON Powerware 5125 (9910-E65) UPS Installation Guide for IBM Applications 164201698 Rev 1...
  • Page 16 (see Figure 7). Repeat for each cabinet. Pan-Head Screws Optional Figure 7. Securing the Mounting Brackets ® ® EATON Powerware 5125 (9910-E65) UPS Installation Guide for IBM Applications 164201698 Rev 1...
  • Page 17 Wing Nuts on Rear Hold-Down Bracket (attached to rail) Rear Hold-Down Bracket (for UPS) Figure 8. Securing the Back of the UPS ® ® EATON Powerware 5125 (9910-E65) UPS Installation Guide for IBM Applications 164201698 Rev 1...
  • Page 18 14. Tighten the pan-head screws that secure both rails to the front of the rack (see Step 3 on page 6). 15. Continue to the following section, “Installing the Internal Batteries.” ® ® EATON Powerware 5125 (9910-E65) UPS Installation Guide for IBM Applications 164201698 Rev 1...
  • Page 19: Installing The Internal Batteries

    Slide the battery trays into the chassis (see Figure 11). Figure 11. Installing the Battery Trays Secure the battery trays to the chassis with the battery retaining bracket and screws removed in Step 3. ® ® EATON Powerware 5125 (9910-E65) UPS Installation Guide for IBM Applications 164201698 Rev 1...
  • Page 20: Ebm Installation

    To install the optional EBM(s): Verify that all battery circuit breakers are in the OFF position (see Figure 13). Plug the EBM cable into the UPS battery connector. ® ® EATON Powerware 5125 (9910-E65) UPS Installation Guide for IBM Applications 164201698 Rev 1...
  • Page 21 EBMs (see “Configuration Mode” on page 30). Battery Circuit Breaker UPS Battery Connector EBM Cable Battery Circuit EBM Battery Breakers Connectors Figure 13. Typical EBM Installation ® ® EATON Powerware 5125 (9910-E65) UPS Installation Guide for IBM Applications 164201698 Rev 1...
  • Page 22: Ups Installation

    “Remote Emergency Power-off Installation” to install the REPO switch before powering on the UPS. Continue to “Power Connections and Startup” on page 19. ® ® EATON Powerware 5125 (9910-E65) UPS Installation Guide for IBM Applications 164201698 Rev 1...
  • Page 23: Remote Emergency Power-Off Installation

    To install the REPO switch: Verify that the UPS is off and unplugged. Remove the REPO connector from the REPO port on the UPS rear panel. ® ® EATON Powerware 5125 (9910-E65) UPS Installation Guide for IBM Applications 164201698 Rev 1...
  • Page 24 Plug in the UPS and start the UPS by pressing the On button for approximately three seconds. Activate the external REPO switch to test the REPO function. De-activate the external REPO switch and restart the UPS. ® ® EATON Powerware 5125 (9910-E65) UPS Installation Guide for IBM Applications 164201698 Rev 1...
  • Page 25: Power Connections And Startup

    UPS output receptacle (see Figure 17) using the supplied power cord. Then plug the second (redundant) PDU power cord into a non-UPS protected output receptacle (mains) or into a second UPS. ® ® EATON Powerware 5125 (9910-E65) UPS Installation Guide for IBM Applications 164201698 Rev 1...
  • Page 26 Normal mode and supplying power to your equipment. If the alarm beeps or a UPS alarm indicator stays on, refer to “Troubleshooting” in the Powerware 5125 Rack-Mount UPS (5000/6000 VA) User’s Guide. The UPS automatically sets the output voltage based on the input voltage.
  • Page 27 RS 3750, 1.8m/6 ft 1423 RS 3750, 4.3m/14 ft 1424 IEC-309 (P+N+G) 32A, 4.3m/14 ft 1425 KP, 4.3m/14 ft 1426 PDL, 4.3m/14 ft 1427 PDL-NZ, 4.3m/14 ft ® ® EATON Powerware 5125 (9910-E65) UPS Installation Guide for IBM Applications 164201698 Rev 1...
  • Page 28 NOTE E65 with 2972 or 2973 has a maximum output capacity of 4500 watts even though IBM PDU 7188 or 9188 can support higher power output. Plan accordingly. ® ® EATON Powerware 5125 (9910-E65) UPS Installation Guide for IBM Applications 164201698 Rev 1...
  • Page 29 7188, 9188, 5889, or 7109 4 4 4 4 iSeries pSeries 7188, 9188, 5889, or 7109 Figure 19. E65 with Non-Redundant Power to Multiple PDUs ® ® EATON Powerware 5125 (9910-E65) UPS Installation Guide for IBM Applications 164201698 Rev 1...
  • Page 30 9188, 5889, or 7109 4 4 4 4 Mains Varies IBM (8) iSeries pSeries 7188, 9188, 5889, or 7109 Figure 20. E65 with Dual-Redundant Power ® ® EATON Powerware 5125 (9910-E65) UPS Installation Guide for IBM Applications 164201698 Rev 1...
  • Page 31: Load Segments

    The E65 has two load segments as shown in Figure 21. Load Segment 1 Load Segment 2 Circuit Breaker Circuit Breaker Load Segment 2 Load Segment 1 Figure 21. UPS Load Segments ® ® EATON Powerware 5125 (9910-E65) UPS Installation Guide for IBM Applications 164201698 Rev 1...
  • Page 32 INSTALLATION This page intentionally left blank. ® ® EATON Powerware 5125 (9910-E65) UPS Installation Guide for IBM Applications 164201698 Rev 1...
  • Page 33: Operation

    The load level and battery indicators flash briefly prior to shutdown. If you do not unplug or remove utility power from the UPS, it remains in Standby mode. ® ® EATON Powerware 5125 (9910-E65) UPS Installation Guide for IBM Applications 164201698 Rev 1...
  • Page 34: Initiating The Self-Test

    If the alarm beeps or a UPS alarm indicator stays on, refer to “Troubleshooting” in the Powerware 5125 Rack-Mount UPS (5000/6000 VA) User’s Guide. Operating Modes The Powerware 5125’s front panel indicates the UPS status through the UPS indicators. Figure 22 shows the UPS front panel indicators and controls. Indicator Legend...
  • Page 35: Normal Mode

    When all of the load level indicators and the indicator are illuminated, power requirements exceed UPS capacity; refer to “Troubleshooting” in the Powerware 5125 Rack-Mount UPS (5000/6000 VA) User’s Guide for more information. Battery Mode When the UPS is operating during a power outage, the alarm beeps μ...
  • Page 36: Bypass Mode

    UPS beeps. The indicator for the selected option indicates the current setting; flashing represents disabled options (see Figure 24 and Table 9). ® ® EATON Powerware 5125 (9910-E65) UPS Installation Guide for IBM Applications 164201698 Rev 1...
  • Page 37 Press the Off button ONCE to Press the Alarm Reset toggle an option on or off. button to save the setting and exit Configuration mode. Figure 24. Using Configuration Mode ® ® EATON Powerware 5125 (9910-E65) UPS Installation Guide for IBM Applications 164201698 Rev 1...
  • Page 38 One EBM is configured. Flashing One of the other EBM configurations is selected. 2 EBMs Two EBMs are configured. Flashing One of the other EBM configurations is selected. ® ® EATON Powerware 5125 (9910-E65) UPS Installation Guide for IBM Applications 164201698 Rev 1...
  • Page 39 Three EBMs are configured. Flashing One of the other EBM configurations is selected. 4 EBMs Four EBMs are configured. Flashing One of the other EBM configurations is selected. ® ® EATON Powerware 5125 (9910-E65) UPS Installation Guide for IBM Applications 164201698 Rev 1...
  • Page 40 OPERATION This page intentionally left blank. ® ® EATON Powerware 5125 (9910-E65) UPS Installation Guide for IBM Applications 164201698 Rev 1...
  • Page 41: Communication Options

    To connect the UPS to an i5, iSeries, or AS/400 and a serial server you need: An Eaton-supplied Relay-Serial Card, an AS/400 interface cable (labeled 152601976-001), and a serial interface cable (labeled 124102044-001), located in the FC 2939 carton labeled “Cable Kit for IBM iSeries and Windows or AIX/Linux Servers”...
  • Page 42 UPS Interface Cable (labeled 1827) Serial Interface Cable AS/400 Interface Cable (labeled 152601976-001) (labeled 124102044-001) Relay-Serial Card Communication Port Figure 25. i5 and Serial Server Interface ® ® EATON Powerware 5125 (9910-E65) UPS Installation Guide for IBM Applications 164201698 Rev 1...
  • Page 43 Serial (TTY) Server Serial Interface Cable (labeled 124102044-001) AS/400 Interface Cable (labeled 152601976-001) Relay-Serial Card Communication Port Figure 26. iSeries or AS/400 and Serial Server Interface ® ® EATON Powerware 5125 (9910-E65) UPS Installation Guide for IBM Applications 164201698 Rev 1...
  • Page 44: Serial (Tty) Interface Overview

    To serially (TTY) connect the UPS to a p5, pSeries, RS/6000 ® OpenPower or other system you need: An Eaton-supplied serial interface cable (labeled 124102042-002 or 116750226-001), located in the E65 accessory kit Powerware LanSafe Power Management Software from the...
  • Page 45: P5 Or Pseries With Logical Partitions Interface Overview

    Logical Partitions Interface Overview To connect the UPS to a p5 or pSeries with LPARs you need: An Eaton-supplied ConnectUPS-X Web/SNMP Card, located in the FC 2934 carton labeled “ConnectUPS-X Web/SNMP Card Kit” NetWatch software from the Software Suite CD, located in the E65...
  • Page 46 COMMUNICATION OPTIONS This page intentionally left blank. ® ® EATON Powerware 5125 (9910-E65) UPS Installation Guide for IBM Applications 164201698 Rev 1...
  • Page 47: Service And Support

    Figure 29. Example of IBM Serial Number Labels Comments We welcome your comments about this manual. Please send your questions or suggestions for improvements to ibm.ups@powerware.com. ® ® EATON Powerware 5125 (9910-E65) UPS Installation Guide for IBM Applications 164201698 Rev 1...
  • Page 48: Applications S 164201698 Rev

    SERVICE AND SUPPORT This page intentionally left blank. ® ® EATON Powerware 5125 (9910-E65) UPS Installation Guide for IBM Applications 164201698 Rev 1...
  • Page 49 92/31/EEC, Amending Directive 89/336/EEC relating to EMC The EC Declaration of Conformity is available upon request for products with a CE mark. For copies of the EC Declaration of Conformity, contact: Eaton Power Quality Oy Koskelontie 13 FIN-02920 Espoo Finland...
  • Page 50 This page intentionally left blank.
  • Page 52 *1642016981* 164201698 1...

Table of Contents