Address
Tone attenuation value difference
680553
between high frequency tone and low
frequency tone in DTMF signals
PSTN: DTMF tone attenuation level after
680554
dialling
ISDN: DTMF tone attenuation level after
680555
dialling
5
680556
Not used
Time between 68054Dh (NCU
680557
parameter 14) and 68054Eh (NCU
parameter 15)
680558
Not used
680559
Grounding time (ground start mode)
68055A
Break time (flash start mode)
68055B
International dial access code (High)
68055C
International dial access code (Low)
68055D
PSTN access pause time
216
Function
Unit
SP2-103-021 (parameter
20).
The setting must be less than
-dBm x 0.5
–5dBm, and should not
exceed the setting at
680552h above.
See Note 5.
-N x 0.5 –3.5
SP2-103-022 (parameter
dBm
21). See Note 5.
-dBm x 0.5
See Note 5
-
Do not change the settings.
This parameter takes effect
1 ms
when the country code is set
to France.
-
Do not change the setting.
The Gs relay is closed for this
20 ms
interval.
The OHDI relay is open for
1 ms
this interval.
For a code of 100:
BCD
68055B - F1
68055C - 00
This time is waited for each
pause input after the PSTN
access code. If this address
contains FF[H], the pause
20 ms
time stored in address
68054F is used.
Do not set a number more
than 7 in the UK.