Ricoh S-C4.5 Field Service Manual page 257

Machine code: d115/d116
Table of Contents

Advertisement

Aut Line Detect
Press [Execute].
Setting this SP classifies the telephone line where embedded RCG-M is connected as either
dial-up or push type, so embedded RCG-M can automatically distinguish the number that
151
connects to the outside line.
• The current progress, success, or failure of this execution can be displayed with
SP5816 152.
• If the execution succeeded, SP5816 153 will display the result for confirmation and
SP5816 154 will display the telephone number for the connection to the outside line.
Line Detect Rst
Displays a number to show the result of the execution of SP5816 151. Here is a list of what
the numbers mean.
0: Success
1: In progress (no result yet). Please wait.
2: Line abnormal
152
3: Cannot detect dial tone automatically
4: Line is disconnected
5: Insufficient electrical power supply
6: Line classification not supported
7: Error because fax transmission in progress – ioctl() occurred.
8: Other error occurred
9: Line classification still in progress. Please wait.
Dial/Push Select
This SP displays the classification (tone or pulse) of the telephone line to the access point
for embedded RCG-M. The number displayed (0 or 1) is the result of the execution of
SP5816 151. However, this setting can also be changed manually.
[0 to 1 / 0 / 1 /step]
0: Tone Dialing Phone
153
1: Pulse Dialing Phone
Inside Japan "2" may also be displayed:
0: Tone Dialing Phone
1: Pulse Dialing Phone 10PPS
2: Pulse Dialing Phone 20PPS
System Service Mode