Ricoh S-C4.5 Field Service Manual page 189

Machine code: d115/d116
Table of Contents

Advertisement

• Multiply this by the power consumption spec for each mode.
• Convert the result to kWh (kilowatt hours)
Here is an example calculation.
Power
Machine
Consumption
(W):
Date
Data: a
Operating
mode
1081.8
Ready
mode
(stand by)
214.0
Energy
mode
(Panel off)
214.0
Low power
mode
153.0
Off/Sleep
mode
7.0
Total Time of Data: d (min.)
Total Time of Data: d/60min. (Hour)
Total Power Consumption of Data: e (Wmin.)
Total Power Consumption of Data: e /60min./1000W (KWH)
Start Time:
SP8941:
Machine
(min.)
Status
Data: b
001:
Operating
Time
21089.0
002:
Standby
Time
306163.0
003:
Energy
Save Time
71386.0
004:
Low
power
Time
154084.0
005:
Off mode
Time
508776.0
Time
Differences
End Time:
(Data:b -
(min.)
Data: c)
Data: c
(min.)
Data: d
21386.0
297.0
308046.0
1883.0
75111.0
3725.0
156340.0
2256.0
520377.0
11601.0
19762.0
329.37
Energy Save
Power
Consumption
(Data:a x
Data:d)
(Wmin.)
Data: e
321294.6
402962.0
7
797150.0
345168.0
81207.0
1947781.60
32.46
187