Btxr Options - Wassp WMB-160F Installation Manual

F series
Table of Contents

Advertisement

Doc. P/N:
WSP-009-002
Version:
V2.3
Issue Date:
July 2014
Installation Manual
BTXR Options Box
The BTXR Options box provides the installing technician with a number of
additional diagnostic tools to help with troubleshooting installation prob-
lems.
Preprocessing will always default to on. This is the application of the calibration
parameters to the Sonar Data.
DC Correction is required for all new BTxR receivers. This function should not
cause problems with older style BTxRs so in general it should be on. The effects
of not having this on when it should be are multiple torch lights of noise appearing
down the sonar display like the noise shown in Figure 31 except more than one
line.
Request Calibration forces the BTxR to perform a new calibration routine
Ping Parameters reloads the BTxR with the default set of ping parameters.
Request Version provides a read-out of the current WASSP software version plus
the DSP Board software revision and NetBurner software revision numbers.
BTXR Image is used to load a new version of the BTXR firmware.
Engineer - This option should not be used. Do not make any changes to any of
the parameters in this box.
Figure 25 – Engineer Utility - Showing Default Values these should not be changed!