4.1.2. SELECTO operations, MC panel

SELECTO is the name for the operation which allows you to store welding parameters. You can
save five sets of MIG welding values. Parameters which can be stored are wire feed speed, welding
voltage and welding dynamics.
In SELECTO operations there are three different operating modes:
SELECTO OFF: Normal MIG welding with independent adjustments for wire feed speed and
voltage, SELECTO functions are not in use.
SELECTO ON: Welding with stored welding values, wire feed speed, welding voltage and welding
dynamics. Only the channel selection switch is operational. Channels are selected according to the
position of the local remote switch. Channels may be switched either with the CHANNEL switch
or through the interface connector by the robot. You can change channels during welding.
Digital display indicates values for wire feed speed and voltage which are stored on the channel in
question. The stored value for welding dynamics can be retrieved by moving the welding dynamics
potentiometer.
SELECTO SET: Settings are stored for indicated channel by using the SAVE switch. The values
currently set for wire feed speed, voltage and welding dynamics are stored in that memory
location.
Programming of memory channel:
1. Select channel 1...5.
2. Set SELECTO mode switch to SET.
3. Find correct values for wire feed speed, voltage and welding dynamics.
4. Store them by using the SAVE switch.
Note! You can check data which you have stored in memory by setting SELECTO mode
switch on position ON, the display will show the values stored in that memory location.
5. Set SELECTO mode switch to position ON and pre-set channels are active.
16 – PROMIG 520R, 120R / 0544