10. TECHNICAL DATA

Promig 520R, Promig 120R
Operating voltage (safety voltage)
Rated power
Max. load
(nominal values)
Operation principle
Diameter of feed roll
Wire feed speed
Filler wires
Wire reel
Gun connector
Operation temperature range
Storage temperature range
Degree of protection
Promig 520R
Dimensions (without handle)
Promig 120R
Dimensions
The products meet conformity requirements for CE marking.
© KEMPPI OY
50 V DC
100 W
60 % ED
500 A
100 % ED
390 A
4-roll feed
32 mm
I
0...18 m/min
II
0...25 m/min
ø Fe, Ss
0,6...2,4 mm
ø Cored wires
0,8...2,4 mm
ø Al
1,0...2,4 mm
max. weight
20 kg
max. size
ø 300 mm
Euro
-20...+40 oC
-40...+60 oC
IP 23
length
620 mm
width
230 mm
height
480 mm
weight
20 kg
length
319 mm
width
152 mm
height
167 mm
weight
8 kg