Specifi Cations; High Altitude Installations - Valor 785JLN Owner's Manual

Direct vent gas insert
Table of Contents

Advertisement

QUALIFIED
INSTALLER
Approval & Codes
This appliance is certifi ed to ANSI Z21.88-2014 / CSA
2.33-2014 American National Standard / CSA Standard
for Vented Gas Fireplace Heaters for use in Canada
and USA, and to CGA 2.17-91 High Altitude Standard
in Canada. This appliance is for direct vent insert
installations.
This appliance complies with CSA P4.1-09 Testing
method for measuring annual fi replace effi ciencies.
The installation must conform to local codes or, in the
absence of local codes, with the National Fuel Gas
Code, ANSI Z223.1 or the Natural Gas and Propane
Installation Code CAN/CGA-B149. Only qualifi ed
licensed or trained personnel should install this
appliance.
This appliance must be electrically grounded in
accordance with local codes, or, in the absence of local
codes, with the National Electrical Code, ANSI/NFPA
70 or the Canadian Electrical Code, CSA C22.1.
Ratings
Model
Gas
Altitude (Ft.)*
Input Maximum (Btu/h)
Input Minimum (Btu/h)
Manifold Pressure (in w.c.)
Minimum Supply Pressure
(in w.c.)
Maximum Supply Pressure
(in w.c.)
Main Burner Injector
Marking
Pilot Injector Marking
Min. Rate By-Pass Screw
16
Specifi cations
NG
LPG
Natural
Propane
0-4,500 feet*
33,000
30,000
17,500
19,000
3.2
9.0
5.0
11.0
10.0
14.0
1000
360
51
30
220
125

*High Altitude Installations

I nput ratings are shown in BTU per hour and are
certifi ed without deration for elevations up to 4,500 feet
(1,370 m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the current
ANSI Z223.1 and/or local codes having jurisdiction.
Heating value of gas in some areas is reduced to
compensate for elevation—consult your local gas utility
to confi rm.
For installations at elevations above 4,500 feet
(1,370 m) in Canada, please consult provincial and/or
local authorities having jurisdiction.
Supply Gas
Heater engine 785JLN is used with natural gas.
Heater engine 785JLP is used with propane gas.
The supply pressure must be between the limits shown
in the Ratings section above.
The supply connection is 1/2" NPT female and located
on the left hand side of the control valve. The gas
line entry point is on the upper left hand side on the
fi replace.
X
X
Conversion Kits
The 785 Legend G4 is supplied as natural gas or
propane gas and is fi eld convertible between fuels. See
instructions packaged with the conversion kit for further
information.
Electrical
The 785 does not require an electrical power source to
operate as a heater. However, if the appliance is fi tted
with a fan, a grounded power source is required.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

785jlpLegend g4

Table of Contents