795CFK CIRCULATING FAN KIT
INSTALLATION and OPERATING INSTRUCTIONS
Note: This kit must be installed or serviced by a qualified installer, service agency or gas supplier.
These instructions are to be used in conjunction with the main installation instructions for the above
listed models.
WARNING: If these instructions are not followed exactly, a fire or explosion may result
causing property damage, personal injury or loss of life.
GROUNDING: This power supply must be installed and grounded in accordance with local codes,
or in the absence of local codes, with the current Canadian Electrical Code CSA C22.1. or in the
USA the National Electrical Code ANSI/NFPA70 latest edition.
Description of System
The models listed above have been designed to
accommodate the installation of a 150CFM air
circulation fan.
Operated via the remote control handset and having
variable speed control, the fan is designed to boost the
natural convection through the heater; this may be a
desirable feature dependent on the fireplace location
and room layout.
It is preferable to install the circulating fan before
the heater is installed although it may also be
retrofitted at a later date provided power is available
at the fan location. However, please note that the
retrofitting of the fan is done by disconnecting the
gas and removing the heater form the cavity. Once
installed, the fan may be serviced from inside the
firebox without removing the heater from the cavity
(780 only).
The fan is designed for automatic operation to come
on and off when the burner comes on and off. The
fan speed can be controlled from the remote control
handset. There are four speeds available. The fan
will start approximately 4 minutes after lighting the
appliance and will continue to run for approximately 10
minutes after the burner is shut off. The fan will go on
and off at the speed last selected by the user.
4002487-02
© 2010, Miles Industries Ltd. All rights reserved.
G4 S
CSA approved for use only with
Valor models 780 and 785
erieS
Operation
To operate the fan, press the "SET" button on the
remote handset until only the fan icon (
on the display and is flashing. Press the up/down
buttons to set the fan speed (
means the fan is OFF. Once the flashing stops, the fan
is set. The fan icon and number of bars will show when
the remote is in other modes to confirm the fan status.
Note: The fan, when plugged in, provides power for
the remote control receiver via the fan control module.
Therefore batteries are no longer required in the
receiver other than for back-up purposes. A battery is
still required in the remote control handset.
Electrical Requirements
The fan kit requires a power supply of 120 Volts,
1 phase, 60 Hz. Full load current is less than 1 amp.
) appears
). No bars showing
1

Advertisement

loading

Summary of Contents for Valor G4 Series

  • Page 1 INSTALLATION and OPERATING INSTRUCTIONS CSA approved for use only with Valor models 780 and 785 Note: This kit must be installed or serviced by a qualified installer, service agency or gas supplier. These instructions are to be used in conjunction with the main installation instructions for the above listed models.
  • Page 2: Install The Fan

    Fan Kits Components The complete 795CFK kit contains the 6-foot following: electrical cord • Fan enclosure: fan and motor unit, control wire; Fan control module Fan enclosure • Fan control module; • Wiring diagram label; • 6-foot power cord. Fan control wire (module to receiver) Wiring diagram Kit 795CFK (as supplied)
  • Page 3 Test the fan Connect the fan to the receiver. a) Pull the fan control wire from the inside back of The fan is operated with the remote control system. It the appliance along to the receiver. has 4 speed levels. On the remote control handset’s display, this icon ( ) represent the fan and this icon ) represents the speed.
  • Page 4 Access for servicing—780 fireplace e) Remove the front log support. WARNING DO NOT TOUCH THE FIREPLACE WHILE IT IS HOT! Let it cool first before any maintenance. Before carrying out any maintenance, make sure the fireplace is turned off including the pilot. MAKE SURE THE FIREPLACE IS COLD! Access the fan.
  • Page 5 Remove the fan. Remove the fan control module. If you need to remove the fan control module, remove WARNING the fan first. The module is on the left hand side of the fan and it is held in place by a piece of Velcro. TO AVOID ELECTRIC SHOCK disconnect the a) Pull the fan out of the enclosure as indicated power to the fan before servicing.
  • Page 6 Access for servicing—785 fireplace Carefully disconnect the fan control wire from the receiver. WARNING DO NOT TOUCH THE FIREPLACE WHILE IT IS HOT! Let it cool first before any maintenance. Before carrying out any maintenance, make sure the fireplace is turned off including the pilot. MAKE SURE THE FIREPLACE IS COLD! control wire...
  • Page 7 Removing the fan or control module Removing the fan control module. The module is held in place by a piece of Velcro. If you need to replace the fan or the control module Disconnect the power, the fan, and the receiver from their enclosure, proceed as follows.
  • Page 8 Wiring Diagram Warning—Electrical Grounding Instructions This appliance is equipped with a three-prong (grounded) plug for your protection against shock hazard and must only be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounded prong from this plug. NOTE - ALL WIRING IS SPECIFIC TO THIS KIT AND SHOULD ONLY BE REPLACED WITH ORIGINAL EQUIPMENT WIRING FROM THE MANUFACTURER Because our policy is one of constant development and improvement, details may vary slightly from those given in this publication.
  • Page 9: Exigences Électriques

    795CFK Guide d’installation et d’opération Homologué par la ACN (CSA) pour usage exclusif avec Valor 780 et 785 les foyers Note : Ce kit doit être installé et entretenu par un installateur qualifié, une agence de service certifiée ou un fournisseur de gaz.
  • Page 10: Contenu Du Kit

    Contenu du kit Le kit 795CFK contient les articles suivants : Cordon d’alimentation de 6 pi (1,9 m) • Boîtier du ventilateur : ventilateur, moteur, fil de commande; Module de commande du Boîtier du ventilateur • Module de commande; ventilateur •...
  • Page 11 Vérifiez l’opération du ventilateur Branchez le ventilateur au récepteur. a) Tirez sur le fil de commande du ventilateur de Le ventilateur à quatre vitesses fonctionne à l’aide de l’intérieur du foyer vers le récepteur. la télécommande. Sur l’écran de la manette, cet icône ) représente le ventilateur et cet icône représente la vitesse d’opération ( ).
  • Page 12 Accès pour entretien—Foyer G4 780 d) Enlevez le support de bûche arrière (3 vis). AVERTISSEMENT NE TOUCHEZ PAS LE FOYER LORSQU’IL EST CHAUD! Laissez-le refroidir avant tout entretien. Avant l’entretien, assurez-vous que le foyer est éteint incluant la veilleuse. ASSUREZ-VOUS QUE LE FOYER EST REFROIDI! Accédez au ventilateur.
  • Page 13 Enlevez le ventilateur. Enlevez le module de commande du ventilateur. Si vous devez enlever le module de commande du AVERTISSEMENT ventilateur, enlevez d’abord le ventilateur. Le module est situé à gauche du ventilateur et il est maintenu en POUR ÉVITER LES CHOCS ÉLECTRIQUES place par une pièce de Velcro.
  • Page 14 Accès pour entretien—Foyer G4 785 Débranchez soigneusement le fil de commande du ventilateur au récepteur. AVERTISSEMENT NE TOUCHEZ PAS LE FOYER LORSQU’IL EST CHAUD! Laissez-le refroidir avant tout entretien. Avant l’entretien, assurez-vous que le foyer est éteint incluant la veilleuse. ASSUREZ-VOUS QUE LE FOYER EST REFROIDI! Fil de commande...
  • Page 15 Remplacement du ventilateur ou de son module de Enlever le module de commande du ventilateur. Le commande module est tenu en place par une pièce de Velcro. Débranchez les bornes du cordon d’alimentation Si vous devez remplacer le ventilateur ou son module (POWER), du ventilateur (FAN), et le fil du module de commande, suivez les étapes ci-dessous.
  • Page 16: Schéma Des Connexions

    Schéma des connexions Avertissement—Directives de mise à la terre Pour votre protection contre les dangers de chocs électriques, ce ventilateur est équipé d’une fiche polarisée à trois lames. La fiche doit être branchée directement dans une prise de courant à trois lames, mise à la terre. Ne pas couper ou enlever la lame polarisée de cette fiche.

This manual is also suitable for:

795cfk