Valor 785ILNV2 Installation And Owner's Manual

Direct vent gas insert

Advertisement

Quick Links

785ILNV2 (NG) & 785ILPV2 (LPG)
Installation and Owner's Manual
WARNING
!
A barrier designed to reduce the risk of burns from the hot viewing
glass is provided with this appliance and shall be installed
for the protection of children and other at-risk individuals.
WARNING: If the information in these
instructions is not followed exactly, a fi re
or explosion may result causing property
damage, personal injury or loss of life.
Do not store or use gasoline or other
fl ammable vapors and liquids in the vicinity
of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light the appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call
the fi re department.
Installation and service must be performed
by a qualifi ed installer, service agency or the
gas supplier.
4002263-V2
©2013, Miles Industries Ltd.
L
EGEND
Direct Vent Gas Insert
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
Miles Industries Ltd.
www.valorfi replaces.com
G4
L e a v e t h i s m a n u a l
w i t h t h e a p p l i a n c e .
R e t a i n t h i s m a n u a l
f o r f u t u r e r e f e r e n c e .
Please read this manual
BEFORE installing and
operating this appliance.
This manual contains instructions to install the
ENGINE ONLY. A front is also REQUIRED to
complete this installation. A barrier screen is pro-
vided with the front. Refer to the manual sup-
plied with the front for installation.
This appliance may be installed in an
after-market permanently located,
manufactured (mobile) home where not
prohibited by local codes.
This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases, unless a certifi ed kit is used.
This appliance is a domestic room-heating
appliance. It must not be used for any other
purposes such as drying clothes, etc.
This appliance is suitable for installation in a
bedroom or bed sitting room.
Ce guide est disponible en français sur demande.
Patent Pending
I N S TA L L E R
C O N S U M E R

Advertisement

Table of Contents
loading

Summary of Contents for Valor 785ILNV2

  • Page 1 EGEND Patent Pending Direct Vent Gas Insert 785ILNV2 (NG) & 785ILPV2 (LPG) Installation and Owner’s Manual WARNING I N S TA L L E R L e a v e t h i s m a n u a l HOT GLASS WILL w i t h t h e a p p l i a n c e .
  • Page 2: Table Of Contents

    Designed and Manufactured by / for Miles Industries Ltd. 190–2255 Dollarton Highway, North Vancouver, BC, CANADA V7H 3B1 Tel. 604-984-3496 Fax 604-984-0246 www.valorfi replaces.com © Copyright Miles Industries Ltd., 2013...
  • Page 3: Safety Precautions

    Safety Precautions READ and UNDERSTAND all instructions carefully This unit MUST be used with a vent system as before starting the installation. FAILURE TO FOLLOW described in this installation manual. NO OTHER vent these installation instructions may result in possible fi re system or components MAY BE USED.
  • Page 4: Safety And Your Fireplace

    Child Safety Precautions and Recommendations, • A physical barrier is strongly recommended if there are young Parts of your Valor Fireplace become • children, or at-risk individuals in the extremely hot while in operation. house. Install an approved after- The glass viewing window •...
  • Page 5: Owner's Information

    For purchasing a Valor by Miles Industries. Your new EXTREMELY HOT!!! radiant gas heater is a technical appliance that must be installed by a qualifi ed dealer. Each Valor fi replace • READ the SAFETY information on pages is fully tested during the production process for your 3 and 4 of this manual BEFORE operating safety and comfort.
  • Page 6 OWNER’S Owner’s Information INFORMATION Cleaning To remove the window: 1. Unhook the trim WARNING WARNING WARNING with the barrier DO NOT TOUCH THE GLASS WHILE IT IS HOT! DO NOT TOUCH THE GLASS WHILE IT IS HOT! screen. Let the fi replace cool fi rst before cleaning it. Let the fi...
  • Page 7 OWNER’S Owner’s Information INFORMATION 3. Apply light hand pressure against the window frame The appliance area must always be kept clear and sides to bed-in the window seal. free from combustible materials, gasoline and other fl ammable vapors and liquids. 4.
  • Page 8 OWNER’S Owner’s Information INFORMATION 5. Replace the cover and screw in place. (including pilot) How to Turn Your Fireplace OFF 6. Reconnect the battery box. Familiarize yourself with each of these methods before 7. Put the battery box back in its position. operating your fi...
  • Page 9: Remote Control Operation

    OWNER’S Remote Control Operation INFORMATION NOTE: Before using the remote control system for IMPORTANT: BEFORE YOU BEGIN, please note that the fi rst time, the receiver and the handset must be on this system, the settings of time, temperature and synchronized.
  • Page 10 OWNER’S Remote Control Operation INFORMATION • Press and hold (small fl ame) MODES OF OPERATION button to decrease fl ame height or • Briefl y pressing the SET button to set the appliance at pilot fl ame. changes the mode of operation in •...
  • Page 11 OWNER’S Remote Control Operation INFORMATION • TO OPEN AND CLOSE DOUBLE BURNER - Nighttime Setback T E M P (785 fi replace models only) Temperature Mode (Appliance must be in standby mode; pilot NOTE: The rear part of the double burner cannot be ac- ignited) - The room temperature tivated manually: it can only function with the re- is measured and compared to the...
  • Page 12 OWNER’S Remote Control Operation INFORMATION SETTING THE “NIGHTTIME SETBACK” SETTING THE ON / OFF TEMPERATURES TEMPERATURE (moon), “ SETTING THE “DAYTIME” TEMPERATURE Default Settings: ” (OFF) T E M P (sun), 23ºC / 74ºF Default Settings: TEMP • Briefl y press SET button to scroll to •...
  • Page 13 OWNER’S Remote Control Operation INFORMATION SETTING P1 OFF TIME SETTING PROGRAM TIMERS • You can program two periods of time between 12:00 • Briefl y press SET button to scroll am and 11:50 pm in each 24-hour cycle. to TIMER (moon) while the •...
  • Page 14: Options

    787EBLV2—Enamel Black Liner Set 1265WSK—Wall Switch Kit 788FBLV2—Fluted Black Liner Set Conversion Kit 789VRLV2—Valor Red Brick Liner Set 785PGK—Conversion Kit to Propane Gas Front (all with Barrier Screen 4003371) 785NGK—Conversion Kit to Natural Gas 790FTV—Floating Trim Kit Vintage Iron (2-1/2”) Hearth Gate 791STB—Square Trim Kit Black (5-3/4”)
  • Page 15: Lighting Instructions

    OWNER’S Lighting Instructions INFORMATION FOR YOUR SAFETY, READ BEFORE LIGHTING WARNING : If you do not follow these instructions exactly A. This appliance has a pilot which must be lighted by hand or by remote control. Follow these instructions exactly. To save gas, turn the pilot off when not using the appliance for a prolonged period of time.
  • Page 16: Specifi Cations

    Installation Code CAN/CGA-B149. Only qualifi ed Supply Gas licensed or trained personnel should install this Heater engine 785ILNV2 is used with natural gas. appliance. Heater engine 785ILPV2 is used with propane gas. This appliance must be electrically grounded in...
  • Page 17: Overview

    QUALIFIED Overview INSTALLER This appliance may ONLY be installed in an existing unaltered, functioning solid-fuel burning fi replace with a working fl ue and constructed of non-combustible material. DO NOT install into combustible construction. This appliance is NOT APPROVED for installation with a zero clearance kit. WARNING WARNING Chimney Terminal Cap...
  • Page 18: Dimensions

    QUALIFIED Dimensions INSTALLER 33” (838 mm) 24” (610 mm) 6’ (1.9 m) Fan power cord 3” (76 mm) Optional fan 3” 3” 15” (76 mm) (76 mm) (381 mm) 15” 4” Trim (381 mm) (102 mm) (sold separately) 10” Gas line approx. 24“ (610 mm) of flex protruding from (254 mm) sheet metal box...
  • Page 19: Clearances

    QUALIFIED Clearances INSTALLER WARNING WARNING Some materials or items, although safe, may discolor, shrink, warp, crack, peel, Some materials or items, although safe, may discolor, shrink, warp, crack, peel, and so on because of the heat produced by the fi replace. Avoid placing candles, and so on because of the heat produced by the fi...
  • Page 20: Venting

    QUALIFIED Venting INSTALLER Typical Vent Installation See list of approved venting accessories on page 36 of this manual. NOTE: Flexible co-linear vent pipes may only be installed into existing non-combustible solid-fuel burning fi replaces Terminal Cap and chimneys. Vent Location The vent terminal must be located through the roof.
  • Page 21: Installation Planning

    QUALIFIED Installation Planning INSTALLER Only qualifi ed licensed or trained personnel should install this appliance. Installer—READ THIS FIRST 13. Refi t window. 1. YOU NEED TO KNOW FROM THE HOMEOWNER what accessories (surround, 14. Reinstall the hot glass warning plate if it has been screen, fan/blower, etc.) will be installed with removed.
  • Page 22: Appliance Preparation

    QUALIFIED Existing Fireplace Preparation INSTALLER Gas Line Routing Combustible Mantels Plan the routing of the gas line before proceeding. Combustible mantel clearances must conform to those Utilize the existing hole for the gas line of the factory- required for the original solid-fuel fi replace into which built fi...
  • Page 23 QUALIFIED Appliance Preparation INSTALLER Window Removal The window is held in place by a spring-loaded lever on each side. 1. To remove the window, locate the levers on each side of the window towards the top. Using your fi nger, pull the lever towards you and unhook it from the window frame bracket.
  • Page 24 QUALIFIED Appliance Preparation INSTALLER Venting Installation IMPORTANT: This appliance’s venting system is room sealed and therefore, does not require room air to be used in the combustion process. 1. Rough-in two 3” diameter vent liners into the existing chimney system from the roof. Be careful not to tear or damage the liners in the process.
  • Page 25: Supply Gas Installation

    QUALIFIED Supply Gas Installation INSTALLER The gas supply inlet connection is a 1/2” NPT female. Pressure Test Points Gas shut-off valve supplied on the end of stainless The minimum supply pressure is given in the section steel fl exible connector. Flex connector is located on Specifi...
  • Page 26 QUALIFIED Supply Gas Installation INSTALLER Use common elbow and fi ttings (not Alternate Inlet Connection supplied) to redirect the position of In cases where local codes do not permit the fl ex the fl ex connector. NOTE: the fl ex connector to be used inside the appliance case, connector bend radius must be no reconnect the fl...
  • Page 27: Burner Removal And Reinstall

    QUALIFIED Burner Removal and Reinstall INSTALLER The ceramic panels can be installed without removing 2. Grab the burner as indicated and gently pull up the the burner. However, you can remove the burner for rear fi rst and then the front. Be careful not to hook additional space if desired.
  • Page 28: Ceramic Logs Installation

    QUALIFIED Ceramic Logs Installation INSTALLER Unpack the ceramic logs very carefully to avoid damaging them. Install the logs as shown below. Please note that the position of the logs is critical to insure proper performance of the appliance. When placing the base and middle logs, rotate them a little bit to anchor them into position. 1.
  • Page 29: Ceramic Logs Installation

    QUALIFIED Ceramic Logs Installation INSTALLER 4. Place the center base log locating its notch on the key in the ember bed as indicated. The darkened part of this log should be on the left side. 5. Place the right-hand base log locating its notch on the key in the ember bed as indicated. 6.
  • Page 30 QUALIFIED Ceramic Logs Installation INSTALLER 8. Place the right-hand cross log locating its notch on the key on the top of the rear log as indicated. Rest the front end of the log centered on top of the center base log. Ensure the logs do not cover the burner holes indicated here...
  • Page 31: Window Refi Tting

    QUALIFIED Window Refi tting INSTALLER 1. To refi t the window, place it in its bottom railing and rotate its top against the fi rebox. 2. While you hold it, pull the side levers back into the Window frame window brackets on each side. IMPORTANT: To ensure a safe operation, verify that the levers are hooked properly to the window tabs;...
  • Page 32: Remote Control Initial Set-Up

    QUALIFIED Remote Control Initial Set-up INSTALLER The receiver and the handset of the remote control 5. With a sharp object, press and hold the receiver’s system must be initially synchronized before the fi rst reset button until you hear one short and one long use.
  • Page 33: Operation Check & Aeration Settings Adjustment

    QUALIFIED Operation Check & Aeration Settings Adjustment INSTALLER In a few unusual installations, the fl ame picture may Operation Check be improved by adjusting the aeration. The need for Turn the fi replace fl ame up and down using the adjustment should be determined only by operating the remote control to confi...
  • Page 34: Side Shrouds Installation

    QUALIFIED Side Shrouds Installation INSTALLER The side shrouds are required to install the front on Door hinge tabs the appliance. They are supplied with the engine. should face inwards Fit them to the appliance outer case as indicated (2 screws/side). Front, Trim and Barrier Screen Installation Install the front or trim chosen by the customer for their Follow the instructions provided with the front or trim...
  • Page 35: Wiring Diagram

    QUALIFIED Wiring Diagram INSTALLER Latching Solenoid Valve Optional Wall Switch Kit 1265WSK Connector Yellow Optional Fan Remote 795CFKV2 Battery Box Control Module 4 AA Batteries GV60 Wiring Diagram...
  • Page 36: Approved Venting Components

    QUALIFIED Approved Venting Components INSTALLER Approved Direct Vent Suppliers for Valor Models 700, 739, 780, 785 and RF24DV Venting Parts Code / availability by Manufacturer Venting Parts Description 4DVC Standard Co-axial 46DVA-VC 4DT-VC TM-4VT — HSDV4658-1313 — 4DH-1313 High Wind Co-axial 46DVA-VCH —...
  • Page 37: Warranty

    OWNER’S Warranty INFORMATION If you have a problem with this unit, please contact your dealer or supplier immediately. Under no circumstances should you attempt to service the unit in any way by yourself. The warranties in paragraphs 1 and 2 are provided only to the fi rst purchaser/user of this unit, are not transferable and are subject to the conditions and limitations in paragraphs 3, 4 and 5.
  • Page 38: Spare Parts

    Thermocouple interrupter 4001037 Enamel black 787EBLV2 GV60 valve assembly NG 4003099 Ceramic fl uted black 788FBLV2 GV60 valve assembly LPG 4003112 Valor red brick 789VRLV2 34” fl ex pipe 4002475 Top panel Solenoid 4002250 Ledgestone 4002368 Rear pipe assembly 4002486...
  • Page 39 Part Code Description Number Left side panel Ledgestone 4002365 Enamel black 4002371EB Ceramic fl uted black 4002377 Valor red brick 4002382 Right side panel Ledgestone 4002366 Enamel black 4002372EB Ceramic fl uted black 4002378 Valor red brick 4002383 Hot glass warning plate...
  • Page 40 OWNER’S Spare Parts INFORMATION 3–7 27a, 27b 32 – 38...
  • Page 41: Miles Industries Ltd

    Thank You ... For purchasing a Valor by Miles Industries. Your new radiant gas heater is a technical appliance that must be installed by a qualifi ed installer. Please fi ll in the information below. The information provided will be used for customer records only.
  • Page 42: Miles Industries Ltd

    Tape Shut Fold here Postage needed Miles Industries Ltd. 190 - 2255 Dollarton Highway North Vancouver, BC V7H 3B1 Canada Online Warranty registration at www.valorfi replaces.com Thank you for choosing a Valor Product...

This manual is also suitable for:

785ilpv2Legend g4 785iln (ng)Legend g4 785ilp (lpg)

Table of Contents