Download Print this page
Valor LEGEND G4 Series Installation Instructions Manual

Valor LEGEND G4 Series Installation Instructions Manual

Gas conversion kit

Advertisement

Available languages

Available languages

Quick Links

This appliance is certifi ed for use from 0–4500 feet. For
altitudes above 4500 feet, see local codes.
Kit Contents
1 Pilot injector
1 Burner
1 Main burner elbow injector
1 Set of conversion labels
1 Set of air shutter
1 Air baffl e for rear log support (LPG only)
4 Screws (for LPG air baffl e)
Tools Required
• Wrenches, to disconnect gas line
• Phillips (+) screwdriver, to remove burner module
• Small (jewelers size) fl at blade screwdriver, to set
pressure
• Small fl at blade screwdriver, to release pressure tap
on valve
• Nut driver 8 mm or 5/16", to remove burner nuts
• Needle nose pliers, to remove by-pass screw
• Hex (Allen) wrench, 4 mm or 5/32", to remove pilot
injector
• Manometer, to set pressure when regulator is integral
with valve
Specifi cations
Model
Gas
Altitude (Ft.)*
Input Maximum (Btu/h)
Input Minimum (Btu/h)
Manifold Pressure (in w.c.)
Minimum Supply Pressure
(in w.c.)
Maximum Supply Pressure
(in w.c.)
Main Burner Injector Marking
Pilot Injector Marking
Min. Rate By-Pass Screw
4002613-03
©2012, Miles Industries Ltd.
L
EGEND
Gas Conversion Kit
780NGK/NPK
Use with with Valor Models 780 Heaters ONLY
Installation Instructions
780NG
780LPG
Natural
Propane
0-4,500 feet*
30,000
28,000
6,500
14,500
4.0
10.5
5.0
11.0
10.0
14.0
850
300
51
30
125
125
G4
WARNING
This conversion kit shall be installed by a
qualifi ed service agency in accordance with
the manufacturer's instructions and all appli-
cable codes and requirements of the authority
having jurisdiction. If the information in these
instructions is not followed exactly, a fi re, ex-
plosion or production of carbon monoxide may
result causing property damage, personal in-
jury or loss of life. The qualifi ed service agency
is responsible for the proper installation of this
kit. The installation is not proper and complete
until the operation of the converted appliance
is checked as specifi ed in the manufacturer's
instructions supplied with the kit.
Use this manual in conjunction with the instal-
lation manual supplied with the appliance.
Burner identifi cation

Advertisement

loading

Summary of Contents for Valor LEGEND G4 Series

  • Page 1 EGEND Gas Conversion Kit 780NGK/NPK Use with with Valor Models 780 Heaters ONLY Installation Instructions This appliance is certifi ed for use from 0–4500 feet. For WARNING altitudes above 4500 feet, see local codes. This conversion kit shall be installed by a Kit Contents qualifi...
  • Page 2: Prepare The Appliance

    General Notes Regarding Conversion 2. Remove the 2 screws securing the burner brackets to the burner tray. The conversion may be done before or after the appliance is installed into the cavity. However, the gas Burner—top view must be connected to set the manifold pressure. Prepare the appliance 1.
  • Page 3 Set and check manifold pressure and 5. Check the aeration and adjust the air shutter if necessary. aeration Set the manifold pressure. 6 mm Flashback AERATION GAP shield 1. Remove the valve access panel (5 screws) on the left hand side of the appliance case. If the appliance is already installed, you will need to pull the left hand side out of the cavity.
  • Page 4 fi tted in 1. 3. Reinstall the right side access door. Designed and Manufactured by / for Miles Industries Ltd. 190–2255 Dollarton Highway, North Vancouver, BC, CANADA V7H 3B1 Tel. 604-984-3496 Fax 604-984-0246 www.valorfi replaces.com © Copyright Miles Industries Ltd., 2012...
  • Page 5: Directives D'installation

    EGEND Kit de conversion de gaz 780NGK/NPK Pour utilisation avec les foyers Valor 780 SEULEMENT Directives d’installation Cet appareil est homologué pour utilisation de 0 à 4 AVERTISSEMENT 500 pieds. Pour altitudes au-dessus de 4 500 pieds, Ce kit de conversion doit être installé par une consultez la règlementation locale.
  • Page 6 À propos de la conversion 2. Enlevez les 2 vis retenant les supports du brûleur à la plaque. La conversion d’un gaz à l’autre peut être faite avant ou après l’installation de l’appareil dans la cavité. Dessus du Cependant, le gaz doit être branché pour régler la brûleur pression d’admission.
  • Page 7 Réglez et vérifi ez la pression d’admission et 5. Vérifi ez l’aération et ajustez l’obturateur d’air si nécessaire. l’aération 6 mm Écran de retour Réglez la pression d’admission. Espace AERATION GAP de fl ammes d’aération 1. Enlevez le panneau d’accès à la soupape (5 vis) à gauche de l’appareil.
  • Page 8 Réinstallez les éléments du foyer Pour réinstaller les éléments du foyer enlevés pour la conversion ou pour compléter l’installation du foyer, consultez le guide d’installation fourni avec le foyer. 1. Réinstallez les panneaux de céramique, le support de briques avant et ensuite le support de bûche arrière (3 vis).

This manual is also suitable for:

Legend g4 780ngkLegend g4 780npk