Table of Contents

Advertisement

10 – Camera program
Label
Noise reduction
Adjust region
Shutter period
10
10.2.5.2
10393203;a3
Figure 10.41 Difference settings dialog box
Difference is a command that calculates the temperature difference between two
measurement markers, or the reference temperature and a measurement marker.
92
Value
On
Off
Normal
Short
Off

Difference

Comments
Move the joystick left/right to enable or disable
noise reduction.
When Noise reduction is set to On, the image
noise decreases and the image appears more
stable.
However, when the camera or the object moves,
and Noise reduction set to On, this may create
some image smearing.
Press the Adjust region button to display a region
on the screen that will be used when autoadjusting
the camera.
Press the joystick left/right to change the shutter
period, or switch off the shutter.
➲ Please note the following:
Although the shutter period works independent-
ly of other functions described in this publica-
tion, FLIR Systems recommends that Short is
selected when using the camera for detection
of face temperature.
Selecting Normal will calibrate the camera at
least every 15th minute, while selecting Short
will calibrate the camera at least every 3rd
minute.
If the shutter is switched off, a symbol (*) will
prefix the result at the time a shutter sequence
should have taken place, thus indicating uncer-
tainty in the measurement result.
Publ. No. 1557966 Rev. a155 – ENGLISH (EN) – February 6, 2006