Creating And Setting Up A Difference Calculation; General; Procedure - FLIR T4xx series User Manual

Hide thumbs Also See for T4xx series:
Table of Contents

Advertisement

16
Working with measurement tools
4. Push the joystick. This displays a submenu.
5. Select
(Set alarm).
6. Push the joystick. This displays a dialog box where you can define the settings for the
alarm.
• Alarm condition: The condition that triggers the alarm. Applicable values are
above, below, or off.
• Select measurement: Applicable settings are the values you have previously de-
fined (max, min, or avg).
• Alarm limit: The temperature value that will be the critical condition when an alarm
is triggered or not.
• Alarm sound: Applicable values are beep or no sound.
7. Push the joystick. This closes the dialog box.
8. Push the joystick and select

16.8 Creating and setting up a difference calculation

16.8.1 General

A difference calculation gives the difference between the values of two known measure-
ment results.

16.8.2 Procedure

Note
You can set up a difference calculation when defining user presets, or when editing an image in the
archive.
This procedure assumes that you have previously laid out at least two measurement tools on the
screen.
16.8.2.1 Procedure
Follow this procedure:
1. To set up a difference calculation, select
2. Push the joystick. This displays a dialog box where you can select the measurement
tools that you want to use in the difference calculation. You can also select a fixed-
temperature reference.
3. Push the joystick. The result of the difference calculation is now displayed on the
screen.
#T559879; r.15723/15723; en-US
(Done).
(Add delta).
44

Advertisement