Adjusting The Combustion Level (Heat Output) - Enerzone Euromax Installation And Operation Manual

Hide thumbs Also See for Euromax:
Table of Contents

Advertisement

6.1.5 Adjusting the Combustion Level (Heat Output)

The stove's input range goes from 10,500 BTU to 70,000 BTU. To change combustion level,
select the flame icon
settings.
Note: Input range may vary according to the type of pellets being used.
Even though your stove can burn a large variety of wood pellets, we strongly recommend the
use of high quality pellets to obtain maximum performance out of your stove (see Section
5.2.1 Proper Fuel). When using lower quality combustible, a restrictive venting system or
using the stove in high altitude, you may need to adjust the "PILOT SETTING ADJUSTMENT"
and the "FUEL QUALITY ADJUSTMENT". These two (2) settings are available from the
"SETUP" page.
Note: To obtain optimal results make sure the venting system, heat exchanger and
exhaust channels are cleaned before performing any setting changes.
30
Press on the
pellet burn rate
adjustment button
on the main status page to display the "+" and "-" combustion level
Euromax Pellet Stove Installation and Operation Manual
Press + or -
to adjust
the burn rate

Advertisement

Table of Contents
loading