3.5 Ceiling Clearances

For ceiling clearances refer to the table in Section 3.2
Minimum Clearances to Combustibles.

3.6 Floor Protection

For floor protection clearances refer to the following table.
FLOOR PROTECTION
LETTER
CANADA
E
18" (457 mm)
F
N/A (USA only)
G
8" (203 mm)
H
8" (203 mm)
CAUTION
: THE STOVE MUST BE PLACED ON A CONTINUOUS (GROUTED JOINTS)
NONCOMBUSTIBLE MATERIAL SUCH AS CERAMIC TILE*, CEMENT BOARD, BRICK,
MILLBOARD OR EQUIVALENT, OR ANY OTHER APPROVED OR LISTED MATERIAL
SUITED FOR FLOOR PROTECTION.
*Any type of tile will require a continuous non combustible sheet beneath to prevent the
possibility of embers falling through to the combustible floor if cracks or separation should
occur in the finished surface, this would include floor protection for built-in raised hearths.
Check local codes for approved alternatives.

4 Venting system

4.1 General

Even though the chimney draft is mechanical, a suitable venting system will ensure a natural
draft which will prevent smoke spillage in your home if a power outage occurs. Moreover, a
suitable venting system configuration will help getting the best efficiency out of your stove
when installed in accordance with the required EVL (see Section 4.3 Equivalent Vent
Length (EVL)).
Even the best stove will not function safely and efficiently as intended if it is not connected to
a suitable venting system.
Euromax Pellet Stove Installation and Operation Manual
USA
6" (152 mm)
6" (152 mm)
N/A (Canada only)
N/A (Canada only)