Stove Operation; First Startup; Everyday Startup; Running Out Of Pellets - Enerzone Euromax Installation And Operation Manual

Hide thumbs Also See for Euromax:
Table of Contents

Advertisement

7 Stove operation

7.1 First Startup

Before starting your stove, make sure that the burn pot, the baffles and the maintenance
access panels are properly installed. Make sure that the stove has been emptied of all tools
and accessories (see Section 2.3: Before Operating Your Stove). Also make sure that the
venting system is properly sealed, that all doors and hopper lid are closed. Make sure that the
hopper is full of pellets. Press the auger icon
AND START" in the displayed page.
If fire doesn't start within 20 minutes, a warning code
Refer to troubleshooting section for more details.
WARNING: NEVER USE A GRATE OR OTHER MEANS OF SUPPORTING THE FUEL.
ONLY USE THE APPROVED STOVE BURN POT.

7.2 Everyday Startup

Before starting the stove, make sure there is enough pellets in the hopper and that the
recommended maintenance schedule has been followed (see Section 8.1.1 Recommended
maintenance schedule) then press the "ON/OFF"
that the button will flash from green to yellow during the igniting mode.

7.3 Running Out of Pellets

If your stove runs out of pellets, the fire will slowly go out; the convection fan will run until the
heat sensor on the exhaust fan reads 115°F. The cooling cycle will take a few minutes before
all other motors stops. When this temperature is reached, a warning message "NO FUEL" will
be displayed on the LCD screen.
To restart the stove, wait until all components stop running (usually 10 minutes after the
warning message has been displayed). Press the "RESET" button, refill the hopper, and
press the auger icon
in the displayed page.

7.4 Refueling

While the stove is running, you have up to 3 minutes to refill the hopper with pellets. Note that
opening the hopper lid will stop the auger from feeding pellets to the stove. If the hopper lid is
left open more than 3 minutes, the stove will stop and a warning code ''HOPPER LID OPEN''
will appear on the LCD screen. To restart the stove, close the lid, press the "RESET" button,
and then press the "ON/OFF" icon
NOTE: Keep hopper lid closed at all times except when refueling. Do not overfill the
hopper.
Euromax Pellet Stove Installation and Operation Manual
on the Main Status Page followed by "FEED AND START" button
on the Main Status Page.
on the Main Status Page and select "FEED
FAILED IGNITION
THE EXHAUST
TEMPERATURE HAS NOT
REACHED ITS START-UP
VALUE AFTER TWO
IGNITION ATTEMPS
icon on the main status page. Note
will appear.
37

Advertisement

Table of Contents
loading

Table of Contents