Defective Igniter Fuse; Auger Fuse - Enerzone Euromax Installation And Operation Manual

Hide thumbs Also See for Euromax:
Table of Contents

Advertisement

9.3.4 Defective Igniter Fuse

v The igniter is defective: Test the resistance (ohms, Ω) with a multimeter. If the value is
near zero, replace the igniter and the F3 fuse.
v The wiring harness shorted. Inspect the wiring and replace any defective wire and or
connector. Make sure the wires are not shorted to the stove frame. Locate the fuse F3 on
the control board and replace it. Go to the troubleshooting page (see Section 9.2 Testing
Components) and follow instructions for component check. Test the igniter to see if it
glows. It should take no longer than two minutes.

9.3.5 Auger Fuse

v The auger is jammed or auger motor failed. Go to the troubleshooting page (see
Section 9.2 Testing components) on the LCD screen and test auger motors. If one of
the motors is not running check if motor is defective or jammed.
NOTE : IF THE HOPPER AUGER MOTOR FAILED OR THE HOPPER AUGER IS
JAMMED, TO AVOID PELLET SPILLAGE, EMPTY THE HOPPER OF ITS CONTENTS
BEFORE EXECUTING THE FOLLOWING TESTS.
o If the auger motor is defective, check to make sure that electrical connections are not
loose and check the fuses F2 and F6 on the control board. If the fuses are good,
remove the faulty auger motor from its auger housing and retest the motor separately
still using the troubleshooting test mode. Make sure the hopper lid is closed. If the
motor functions, the auger may be jammed by a foreign object. If no signs of blockage
are found, call your dealer or a service technician to perform a complete testing.
58
Euromax Pellet Stove Installation and Operation Manual