o If the hopper auger is jammed, start by emptying the hopper. If it is the burn pot auger
you don't need to empty the hopper. To remove both augers from their housing you
need to disconnect auger motor and then remove the four screws on the steel plate
that holds the auger shaft to the auger housing. You may need to remove the rear
panel for an easier access. Pull out the auger from the housing. Once the auger has
been removed, make sure there are no metal flows, burrs, or broken welds. Remove
any foreign material that may have caused the jam. Inspect the auger housing for signs
of damage such as burrs, rough spots, or grooves cut into the metal that could have
caused a jam. Clean the auger housing thoroughly to remove all pellet dust.
v The wiring harness shorted. Make sure the auger motor wiring is properly connected
and not shorted.

9.3.6 Unit Overheat

v Inadequate fuel is used. Remove the burn pot, make sure that all openings are clear and
check that no ash has filled the tube around the igniter. Refer to the maintenance section.
Also, make sure that the recommended fuel is used (see Section 5.2.1 Proper Fuel).
v The flue is not properly installed. Make sure the venting system meets the criteria in the
Section 4: Venting System as well as the venting system manufacturer's instructions.
v The flue is blocked or needs cleaning. One of the following components is obstructed or
blocked; air intake shutter, combustion blower, burn pot, heat exchangers and channels,
exhaust blower and or venting system. Refer to Section 8: Maintenance.
v The stove needs maintenance. Refer to Section 8: Maintenance.
v The burn pot is not installed properly. Make sure the burn pot is installed correctly (see
Section 8.1.4: Cleaning the Burn Pot).
v The baffle is not installed properly or holes may be blocked. Make sure the baffle is
well installed and the lock is in place. Make sure the holes are clear. (see Section 8.1.2:
Cleaning the Baffle, the Heat Exchanger and the Combustion Chamber).
v The convection blower is defective. Go to the troubleshooting page on the LCD screen
and test the convection blower (see Section 9.2 Testing Components).
v The convection blower needs maintenance. Carefully clean blower housing and make
sure blower louvers are not blocked.