Through An Existing Masonry Fireplace - Enerzone Euromax Installation And Operation Manual

Hide thumbs Also See for Euromax:
Table of Contents

Advertisement

4.5.5 Through an Existing Masonry Fireplace

1. Position stove, following clearances
shown
in
Section
Clearances
to
following
vent
instructions.
2. Build and Install a blocking plate inside
the chimney to seal the fireplace
damper.
Stainless
screws are recommended. Cut a hole
for the exhaust pipe. If needed, cut a
second hole for the air intake pipe (see
Appendix F: Combustion Air Supply).
3. Attach a section of pipe and clean out
tee to the exhaust, making sure the
clean out tee is centered in the chimney
flue area.
4. Install a vented flashing at the top of the
fireplace chimney. Stainless steel plate
and screws are recommended. Cut a
hole for the vent pipe. If needed, cut a
second hole for the air intake pipe. Seal
all
joints
with
waterproof silicone sealant to prevent
water leakage.
5. Seal and install vertical roof vent. If
required, seal and install a storm collar.
NOTE: THE STRUCTURAL CONDITION OF THE MASONRY CHIMNEY MUST FIRST BE
INSPECTED BY A QUALIFIED CHIMNEY SWEEP OR INSTALLER.
NOTE: YOU WILL NEED A PIPE LENGTH EQUAL TO THE CHIMNEY HEIGHT FROM THE
HEARTH. IF OUTSIDE COMBUSTION AIR IS TO BE USED, YOU WILL NEED A PIPE
LENGTH SUPERIOR FROM 12 TO 18 INCHES (30 TO 46 CM) OF THE CHIMNEY HEIGHT
TO ENSURE A PROPER STOVE BEHAVIOUR.
Euromax Pellet Stove Installation and Operation Manual
3.2
Minimum
Combustibles
and
manufacturer's
steel
plate
and
high
temperature
12"-18"
21