Remote Tone Control Configuration Example; Ip-223 Setup - Telex IP-223 to RTS Intercom System Application Note

Table of Contents

Advertisement

6.0 Remote Tone Control Configuration Example

FIGURE 14. Remote Tone Control Example
Line to Line Crosspatch, see Figure 14, is enabled in the IP-223. Control logic and audio (6-wire
E&M) are generated by the RTS system; these are connected to Line 2 I/O on the IP-223 which is
configured for Local mode operation. Line 1 I/O of the IP223 is configured for Tone mode
operation and is connected to a 2- or 4-wire lease line for Tone Remote operation of a LMR
mobile radio. Industry standard radio control tones are generated and coupled with voice audio for
control of distant radio locations. Control tones are decoded by either a Telex TRA-223 or
DSP-223 Tone Remote Adaptor which is directly connected to the LMR radio.
Receive audio from the LMR is connected to the I/O of the DSP-223 and amplified down the
2- or 4-wire line to Line 1 I/O of the IP-223. The IP-223 based on LAM passes audio to Line 2 of
the IP-223 and out to the RTS Intercom System for playback at keypanels. PTT commands on a
keypanel generate a relay closure and audio is inserted on Line 2 of the IP-223 COR and audio
inputs. This creates a PTT tone generation sent out Line 1 of the IP-223 onto the 2- or 4-wire line
to the remote radio adaptor, the tone is decoded and a relay closure to key the LMR is generated,
audio is coupled and passed to the radio.

6.1 IP-223 Setup

The IP-223 must be configured for tone mode operation on line 1 and local mode on Line 2.
The IP-223's default username is admin and the password is blank.
NOTE:
REFERENCE:
AN-DISPATCH-035
For more information, see the IP-223 Technical Manual (P/N 803641) for
jumper settings relevant to the RTS equipment to be connected.
IP-223 to RTS Intercom Products
21