Remote Ip-223 Per Line Setup Windows Line 1 And 2 - Telex IP-223 to RTS Intercom System Application Note

Table of Contents

Advertisement

IP-223 to RTS Intercom Products
To configure the Rx and Tx port numbers, do the following:
From the remote IP-223 Multicast Address Setup window, in:
1. Line 1's Rx Port field, enter the same port number as the local IP-223's Tx port
2. Line 1's Tx Port field, enter the same port number as the local IP-223's Rx port
3. Line 2's Rx Port field, enter the same port number as the local IP-223's Tx port
4. Line 2's Tx Port field, enter the same port number as the local IP-223's Rx port
5. Click Save to EEPROM.
6. Click Save Parameters.
NOTE:
FIGURE 13. Multicast Address Setup Window, WAN/LAN Configuration–Remote IP-223

5.2.2 Remote IP-223 Per Line Setup Windows Line 1 and 2

REFERENCE:
20
number for Line 1 (for example 1072).
number for Line 1 (for example 1054).
number for Line 2 (for example 1073).
number for Line 2 (for example 1055).
The EEPROM window appears.
All configurations are permanently saved to the IP-223 console.
The range for the Rx Port field and Tx Port field is 1054 to 65535.
For more information, see the IP-223 Technical Manual (P/N
803641) or appropriate application note for any special IP-223
configuration requirements on Line 1 and Line 2 for the type of
radio connected.
AN-DISPATCH-035

Advertisement

Table of Contents
loading

Table of Contents