IP-223 to RTS Intercom Products

6.1.3 Per Line Setup Window Line 2

Depending on the connection to the RTS equipment, VOX or COR triggering may
be used. If a relay closure from the RTS equipment is supplied, the COR Enabled
check box must be selected on Line 2's Per Line Setup window. An example is
shown in Figure 17.
To configure an RTS supplied relay closure for a remote tone control system, do
the following:
1. Click Per Line Setup.
2. Select the COR Enabled check box. See Figure 17.
3. Click Submit.
FIGURE 17. Per Line Set Window, Local Mode–Line 2
24
The Per Line Setup window appears.
The Per Line Setup configurations are temporarily saved.