Local Ip-223 Per Line Setup Window Lines 1 & 2 - Telex IP-223 to RTS Intercom System Application Note

Table of Contents

Advertisement

IP-223 to RTS Intercom Products
5.1.2 Local IP-223 Per Line Setup Window Lines 1 & 2
Depending on the connection to the RTS equipment, VOX or COR triggering maybe
used.
To configure an RTS supplied relay closure for a WAN/LAN system, do the
following:
1. Click Per Line Setup.
2. Click Line Select 2.
3. Select the COR Enabled check box.
4. Click Submit.
5. Click Save to EEPROM.
6. Click Save Parameters.
To configure PTT with VOX for a WAN/LAN system, do the following:
1. In the LAM Level dB field, enter the level in dB.
2. In the LAM Time field, enter three (3) seconds.
3. Click Submit.
4. Click Save to EEPROM.
5. Click Save Parameters.
NOTE:
FIGURE 12. Per Line Setup Window WAN/LAN, Local Mode–Line 2
18
The Per Line Setup window appears.
The Per Line Setup window for Line 2 appears.
The Multicast Address Setup configuration is temporarily saved.
The EEPROM window appears.
All configurations are permanently saved to the IP-223 console.
The Multicast Address Setup configuration is temporarily saved.
The EEPROM window appears.
All configurations are permanently saved to the IP-223 console.
The recommended LAM level is -20dB to -25dB.
AN-DISPATCH-035